Socket at the PC housing
Supplied mains power unit
Current carrying capacity
of the 100-240 V power
supply unit
Current carrying capacity
of the 24 V power supply
unit
C33xx

Power Supply Connection

The 5-pin CAGE CLAMP plug connector and mounting flange illustrated is
located on the PC housing in order to connect the power supply.
Technical data
Number of contacts
Contact spacing
Minimum conductor cross-section
Minimum conductor cross-section
Rated voltage (EN)
Rated voltage (CSA)
Current EN [A]
Current CSA [A]
Length of stripped conductor
The Industrial PC is either fitted with a 100-240 V, 50-60 Hz power supply
unit (standard) or with a 24 V
uninterruptible power supply, UPS).
Current carrying capacity of the 100-240 V power supply
unit
Output voltages from
the 100-240 V power
supply unit
+3.3 V
+5 V stand by
+5 V
-5 V
+12 V
-12 V

Current carrying capacity of the 24 V power supply unit

Output voltages from
the 24 V power supply
unit
+5 V
-5 V
+12 V
-12 V
Connecting socket
5
5 mm
1.5 mm²
16
(AWG)
250 V
300 V
12 A
15 A
8 to 9 mm
power supply unit (with the option of an
DC
Current loading
maximum
20 A
2 A
25 A
0.3 A
13 A
0.8 A
Current loading
maximum
25 A
1 A
10 A
1.5 A
Installation Instructions
13