Beckhoff CP62 Series Installation And Operating Instructions Manual

Beckhoff CP62 Series Installation And Operating Instructions Manual

Built-in panel pc
Table of Contents

Advertisement

Installation and Operating instructions for
Built-in Panel PC CP62xx
Version: 1.7
Date:
2007-10-19

Advertisement

Table of Contents
loading

Summary of Contents for Beckhoff CP62 Series

  • Page 1 Installation and Operating instructions for Built-in Panel PC CP62xx Version: 1.7 Date: 2007-10-19...
  • Page 3: Table Of Contents

    General Notes Table of contents General Notes Notes on the documentation Liability conditions Description of safety symbols Basic safety measures Operator's obligation to exercise diligence Operator requirements Product Description Appropriate Use Interfaces Fieldbus Serial interface DVI (Digital Visual Interface) USB-Interfaces Network connection Power supply Additional plug-in cards (optional)
  • Page 4 General Notes UPS Software Components (optional) Installation on the PC Help files Troubleshooting Fault correction Service and Support Beckhoff's branch offices and representatives Beckhoff headquarters Beckhoff Support Beckhoff Service Appendix Technical data Approvals FCC: Federal Communications Commission Radio Frequency Interference...
  • Page 5: General Notes

    © This documentation is protected by copyright. Any reproduction or third party use of this publication, whether in whole or in part, without the written permission of Beckhoff Automation GmbH, is forbidden. Description of safety symbols The following safety symbols are used in this operating manual. They are intended to alert the reader to the associated safety instructions.
  • Page 6: Basic Safety Measures

    General Notes Basic safety measures Only switch the PC off after Before the Industrial PC is switched off, software that is running must closing the software be properly closed. Otherwise it is possible that data on the hard disk is lost. Please read the section Switching the Industrial PC on and off.
  • Page 7: Operator's Obligation To Exercise Diligence

    General Notes Operator's obligation to exercise diligence The operator must ensure that • the Industrial PC is only used for its intended purpose (see Product Description section); • the Industrial PC is only operated in a sound condition and in working order;...
  • Page 8: Product Description

    Product Description Product Description Appropriate Use The CP62xx Build-in Panel PC is designed for industrial application in machine and plant engineering. A steel plate housing with aluminum front contains a TFT display, touch screen/ pad (optional) and a PC keyboard (optional).
  • Page 9: Installation Instructions

    4. Please keep the associated paperwork. It contains important information for handling the unit. 5. Check the contents for visible shipping damage. 6. If you notice any shipping damage or inconsistencies between the contents and your order, you should notify Beckhoff Service. CP62xx...
  • Page 10: Installation Of The Pc In The Control Cabinet

    Installation Instructions Installation of the PC in the control cabinet The Built-in Panel PC CP62xx is designed for mounting in control cabinets in machine and plant engineering applications. The ambient conditions specified for operation must be observed (see the section on Technical data).
  • Page 11: Assembly Dimensions

    Installation Instructions Assembly dimensions Build-in Panel PC CP62xx All dimensions are in mm, Similar picture. Dimensions CP620x CP6201 12"-Display 24.6 32.5 CP6202 15"-Display 41.2 CP6203 19"-Display 77.2 Dimensions CP621x 12"-Display 372.2 342.2 358.2 328.2 32.5 CP6211 15"-Display 430.4 416.4 86.5 CP6212 19"-Display 508.4...
  • Page 12: Mounting Of The Panel-Pc

    Installation Instructions Mounting of the Panel-PC Please refer to the tables for Panel-PC cutout dimensions. Mounting of the Panel-PC Clamping levers Release clamping levers, Insert the PC into the cutout. Release the clamping levers with a No. 2.5 Allen key. Folding them out Turn the clamping levers to the side through 90°...
  • Page 13: Power Supply Connection

    Installation Instructions Power Supply Connection Supplied mains power unit The Industrial PC is fitted with a 24 V power supply unit . Optional an uninterruptible power supply (UPS) can be realized using the battery pack C9900-U330. Danger of Explosion if using other battery packs! Danger Pin assignment of the connector The power supply and the external circuit for switching the Industrial PC on...
  • Page 14: Fitting The Cable

    Installation Instructions Fitting the cable Wiring in accordance with Fit the cables for the power supply of the Industrial PC, the connection of wiring diagram the battery pack as well as the connection of the power-switch in accordance with the wiring diagram, using the included material for assembling the connectors.
  • Page 15: Connecting Power Supply

    Installation Instructions Connecting Power Supply The external wiring consists of the connection of the power supply, the battery pack (optional) and the connection of customised components for shutting down the PC. Cable Cross Sections Note cable cross sections, For the connection of the power supply, wiring with a cable-cross-section of 1.5 mm must be used.
  • Page 16: Wiring Diagram

    Installation Instructions Wiring diagram Wiring according to the wiring diagram (the circuit of PC_ON and Power- Status is symbolical): Wiring diagram external switch and power supply Connecting devices The power supply plug must be withdrawn! Warning Please read the documentation for the external devices prior to connecting them.
  • Page 17: Check Voltage Rating And Connect

    • Reconnect all devices to the power supply. Check voltage rating and connect Fitted with the 24 V power supply unit: 1. Check that the external power supply is providing the correct voltage. 2. Insert the power supply cable that you have assembled (see the section Fitting the cable) into the Industrial PC's power supply...
  • Page 18: Operating Instructions

    Operating Instructions Operating Instructions Please also refer to chapter General Notes. Switching the Industrial PC on and off Switch on The Industrial PC does not have its own mains switch. The Industrial PC will start when the equipment is switched on, or when it is connected to the power supply.
  • Page 19: Keyboard Codes

    Operating Instructions Keyboard codes Type-dependent number of Depending on the precise type, the Control Panel can have fewer keys keys than those described here. Operation The cursor is the blinking character that marks the point at which the next character entered will be displayed. The cursor is also known as the insertion point.
  • Page 20 Operating Instructions The function of the special keys above the display is also determined by Einschub Einschub Einschub Einschub the software. The function is displayed at the top edge of the display. Streifen Streifen Streifen Streifen The special keys each have an orange LED controlled by the software. CP62xx...
  • Page 21: Servicing And Maintenance

    Operating Instructions Servicing and maintenance Please also refer to chapter General Notes. Cleaning the Industrial PC Switch off the Industrial PC and all connected devices, and disconnect the Industrial PC from the power supply. Danger The Industrial PC can be cleaned with a soft, damp cloth. Do not use any aggressive cleaning materials, thinners, scouring material or hard objects that could cause scratches.
  • Page 22: Lamp Sets

    Operating Instructions Replacement for the First release the two screws 15 inch display (1) and (2) with a small Philips screwdriver, then carefully pull out the fluorescent lamps in direction of the arrows. After the exchange of the fluorescent lamps the installation takes place in reverse order.
  • Page 23: Ups Software Components (Optional)

    The driver software comes with a detailed help function. System The help files can be called up either directly from the configuration register by clicking the Help button, or under via Start > Programs > Beckhoff > UPS software components. CP62xx...
  • Page 24: Troubleshooting

    Nothing happens after the Industrial No power supply to the Industrial Check power supply cable. PC has been switched on Other cause. Call Beckhoff Service. The Industrial PC does not boot Floppy disk or CD in the drive. Remove floppy disk or CD fully and press any key.
  • Page 25: Service And Support

    Fax: +49(0)5246/963-198 e-mail: info@beckhoff.com Beckhoff Support Support offers you comprehensive technical assistance, helping you no only with the application of individual Beckhoff products, but also with other, wide-ranging services: • world-wide support • design, programming and commissioning of complex automation systems •...
  • Page 26: Appendix

    Appendix Appendix Technical data Dimensions Dimensions (W x H x D): see section Assembly dimensions. Operation in areas that are The Industrial PC must not be used where there is a risk of explosion. subject to explosion hazard The following conditions must be observed during operation: Environmental conditions Ambient temperature: 0 to 55°C...