Summary of Contents for Beckhoff C5101

  • Page 1 Installation and Operating instructions for 19 Inch Rack Mount Industrial PC C5101 Version: 1.5 Date: 2008-06-09...
  • Page 3 First switching on and driver installation Maintenance Cleaning the Industrial PC Replacing the battery on the motherboard Servicing Changing the filter mat Shutting down Disposal Troubleshooting Fault correction Beckhoff Support & Service Beckhoff branches and partner companies Beckhoff Headquarters Beckhoff Support Beckhoff Service C5101...
  • Page 4 Table of contents Assembly dimensions Appendix Technical data Approvals FCC: Federal Communications Commission Radio Frequency Interference Statement FCC: Canadian Notice C5101...
  • Page 5: General Notes

    © This documentation is copyrighted. Any reproduction or third party use of this publication, whether in whole or in part, without the written permission of Beckhoff Automation GmbH, is forbidden. Description of safety symbols The following safety symbols are used in this operating manual. They are intended to alert the reader to the associated safety instructions.
  • Page 6: Basic Safety Measures

    If metal objects such as screws or tools fall onto operating circuit boards. • If connecting cables internal to the PC are removed or inserted during operation. • If plug-in cards are removed or inserted when the PC is switched C5101...
  • Page 7: Operator's Obligation To Exercise Diligence

    Read the operating Every user of the Industrial PC must have read these operating instructions instructions. Software knowledge Every user must be familiar with any of the functions of the software installed on the PC that he can reach. C5101...
  • Page 8: Product Description

    Product Description Product Description Appropriate Use The C5101 Industrial PC has been designed as a rack mount PC for fitting into 19 inch racks used in machine and plant engineering applications. Structure Front view of the C5101 Opening the front flap In order to gain access to the power pushbutton and to the drives, open the flap on the front with the key provided for the purpose (see photo above).
  • Page 9 In order to open the PC housing, remove the 4 fastening screws at the side of the housing cover (see photo Rear view of the C5101) using a cross- head screwdriver. The cover of the housing can then be lifted up, providing access to the hard drive, processor, memory and plug-in cards (see following photograph).
  • Page 10: Interfaces

    Industrial PC Serial interfaces RS 232 The basic version of the C5101 Industrial PC has two serial interfaces, COM1 (1) and COM2 (2), using the type RS232, which are brought to a 9 COM1 - COM2 pin SUB-D plug connector.
  • Page 11: Interfaces Behind The Front Flap

    The LED HDD (3) indicates HDD access. USB interfaces USB4 – USB5 The two USB interfaces (4) are used to connect peripheral devices with USB connections. USB2.0 standard is supported. Power pushbutton Power pushbutton The Industrial PC is switched on via the power-pushbutton (5). C5101...
  • Page 12: Installation Instructions

    6. If you notice any shipping damage or inconsistencies between the contents and your order, you should notify Beckhoff Service. Installation The C5101 Industrial PC is designed for rack mounting in machine and plant engineering applications. The ambient conditions specified for operation must be observed (see the...
  • Page 13: Power Supply Connection

    Listed, Detachable, maximum 4.5 m (14.76 ft.) long; rated minimum 250 V, 10 A, Type SJT or Type SVT; one end terminates in NEMA 6-15P/-20P grounding-type attachment plug, other end in appliance coupler. C5101...
  • Page 14: Connecting Devices

    Reconnect all devices to the power supply. Check voltage rating and connect. 1. Check that the mains voltage is correct. 2. Insert the power supply cable into the power supply socket on the Industrial PC, and plug it into an earthed power socket. C5101...
  • Page 15: Operating Instructions

    If the PC was ordered without operating system, you have to install the operating system and the driver software for any auxiliary hardware yourself. Please follow the instructions in the documentation for the operating system and the additional devices. C5101...
  • Page 16: Maintenance

    If the Industrial PC is used in an environment where the air is particularly dirty, the fan's filter mat should be examined at regular intervals to see how dirty it is, and should be exchanged, if necessary, for an original Beckhoff filter mat (item number C9900-Z213, filter mat for C510x, 10 per pack).
  • Page 17: Shutting Down

    Nothing happens after the Industrial No power supply to the Industrial Check power supply cable. PC has been switched on Other cause. Call Beckhoff Service.. The Industrial PC does not boot CD in drive. Remove CD and press any fully key.
  • Page 18: Beckhoff Support & Service

    Please contact your Beckhoff branch office or partner company for local support and service on Beckhoff products! The contact addresses for your country can be found in the list of Beckhoff branches and partner companies: www.beckhoff.com You will also find further documentation for Beckhoff components there.
  • Page 19: Assembly Dimensions

    Assembly dimensions Assembly dimensions The following page show diagrams of the Industrial PC, with dimensions in The assembly of the unit must take place with the orientation diagrammed here. Warning Front view Industrie-PC C5101 Top view Side view C5101...
  • Page 20: Appendix

    IP20 Power supply Supply voltage: 100-240 V 50-60 Hz 100-240 V power supply Power consumption: C5101-0020: 68 W for the basic version unit C5101-0030: 93 W for the basic version Electromagnetic Interference resistance: according to EN 61000-6-2 Compatibility (EMC) Emitted resistance:...