Beckhoff C6250-0060 Installation And Operating Instructions Manual
Beckhoff C6250-0060 Installation And Operating Instructions Manual

Beckhoff C6250-0060 Installation And Operating Instructions Manual

Control cabinet pc
Table of Contents

Advertisement

Quick Links

Installation and Operating instructions for
Control Cabinet PC
C6250 up to -0060
Version: 1.6
Date:
2018-02-16

Advertisement

Table of Contents
loading

Summary of Contents for Beckhoff C6250-0060

  • Page 1 Installation and Operating instructions for Control Cabinet PC C6250 up to -0060 Version: 1.6 Date: 2018-02-16...
  • Page 3: Table Of Contents

    Interfaces up to C6250-0050 PS/2 connections Parallel interface Serial interfaces Video connection USB interfaces Network connection Sound-On-Board Additional plug-in cards (optional) Interfaces C6250-0060 PS/2 connections Serial interfaces USB interfaces Network connection Sound-On-Board DVI-I (Digital Visual Interface) DVI-D (Digital Visual Interface) DisplayPort...
  • Page 4 Table of contents Troubleshooting Fault correction Service and Support Beckhoff's branch offices and representatives Beckhoff headquarters Beckhoff Support Beckhoff Service Assembly dimensions Appendix Technical data Approvals FCC: Federal Communications Commission Radio Frequency Interference Statement FCC: Canadian Notice C6250...
  • Page 5: General Instructions

    All the components are supplied in particular hardware and software configurations appropriate for the application. Modifications to hardware or software configurations other than those described in the documentation are not permitted, and nullify the liability of Beckhoff Automation GmbH & Co.KG. Delivery conditions In addition, the general delivery conditions of the company Beckhoff Automation GmbH &...
  • Page 6: Description Of Safety Symbols

    General instructions Description of safety symbols The following safety symbols are used in this operating manual. They are intended to alert the reader to the associated safety instructions. This symbol is intended to highlight risks for the life or health of personnel. Danger This symbol is intended to highlight risks for equipment, materials or the environment.
  • Page 7: Operator's Obligation To Exercise Diligence

    General instructions Operator's obligation to exercise diligence The operator must ensure that • the Industrial PC is only used for its intended use (see also Product Description). • the Industrial PC is in a sound condition and in working order during operation.
  • Page 8: Product Description

    Product Description Product Description Appropriate Use The C6250 Industrial PC is designed for mounting in control cabinets in machine and plant engineering applications. The ambient conditions specified in the technical data (see Appendix) must be observed for both operation and storage of the C6250 Industrial PC. Structure Front view of the C6250 (Similar photograph)
  • Page 9 Product Description View of the open PC Under the housing cover (1) is a 7 slot computer core with standard ATX motherboard (2) and power supply unit (3). The connections are located at the front of the housing (4). C6250...
  • Page 10: Interfaces Up To C6250-0050

    Product Description Interfaces up to C6250-0050 ATX motherboard interfaces PS/2 connections PS/2 The upper PS/2 connector (1) allows a PS/2 mouse to be used, while a PC keyboard can be connected to the lower PS/2 connector (2). Parallel interface Printer The parallel interface (3) corresponds to the Centronics standard, and is LPT1 addressed by the software as LPT1.
  • Page 11: Interfaces C6250-0060

    Product Description Interfaces C6250-0060 ATX motherboard X116 X105 interfaces X104 X117 X115 X112 X113 X103 X118 X109 X111 X114 X119 X108 X110 PS/2 connections PS/2 The upper PS/2 connector (X104) allows a PS/2 mouse to be used, while a PC keyboard can be connected to the lower PS/2 connector (X103).
  • Page 12: Installation Instructions

    4. Please keep the associated paperwork. It contains important information for handling the unit. 5. Check the contents for visible shipping damage. 6. If you notice any shipping damage or inconsistencies between the contents and your order, you should notify Beckhoff Service. C6250...
  • Page 13: Installation Of The Pc In The Control Cabinet

    Installation Instructions Installation of the PC in the control cabinet The C6250 Industrial PC is designed for mounting in control cabinets in machine and plant engineering applications. The ambient conditions specified for operation must be observed (see the section on Technical data).
  • Page 14: Power Supply Connection

    Installation Instructions Power Supply Connection The 5-pin CAGE CLAMP plug connector and mounting flange illustrated is located on the PC housing in order to connect the power supply. Socket at the PC housing Technical data Connecting socket Number of contacts Contact spacing 5 mm Minimum conductor cross-section...
  • Page 15: Fitting The Power Supply Cable

    Installation Instructions Fitting the Power Supply Cable Coding pieces The connectors are coded differently at the factory, using snap-on coding pieces, according to the power supply unit that has been fitted. Differently coded plug connectors Coding for the 24 V power supply Coding for the 100-240 V unit...
  • Page 16: Pin Assignment And Cable Requirements

    Installation Instructions Pin assignment and cable requirements Pin assignment There is an adhesive label with the pin assignments on the top of the female plug connector. The minimum permitted conductive cross- section is 1.5 mm², fused for 10 A (AWG 16). Industrial PCs with 100-240 V , 50-60 Hz power supply unit Pin assignment for the...
  • Page 17: Connecting Devices

    Installation Instructions Connecting devices The power supply plug must be withdrawn! Warning Please read the documentation for the external devices prior to connecting them. During thunderstorms, plug connector must neither be inserted nor removed. When disconnecting a plug connector, always handle it at the plug. Do not pull the cable! Connecting cables The connections are located on the front of the Industrial PC, and are...
  • Page 18: Operating Instructions

    Operating Instructions Operating Instructions Please also refer to chapter General instructions. Switching the Industrial PC on and off Switch on The Industrial PC does not have its own mains switch. When the plant is switched on, or when it is connected to its power supply, the Industrial PC will start up.
  • Page 19: Maintenance

    Operating Instructions Maintenance Please also refer to chapter General instructions. Cleaning the Industrial PC Switch off the Industrial PC and all connected devices, and disconnect the Industrial PC from the power supply. Danger The Industrial PC can be cleaned with a soft, damp cloth. Do not use any aggressive cleaning materials, thinners, scouring material or hard objects that could cause scratches.
  • Page 20: Troubleshooting

    Nothing happens after the Industrial No power supply to the Industrial Check power supply cable. PC has been switched on Other cause. Call Beckhoff Service. The Industrial PC does not boot Floppy disk or CD in the drive. Remove floppy disk or CD fully and press any key.
  • Page 21: Service And Support

    Fax: +49(0)5246/963-198 e-mail: info@beckhoff.com Beckhoff Support Support offers you comprehensive technical assistance, helping you no only with the application of individual Beckhoff products, but also with other, wide-ranging services: • world-wide support • design, programming and commissioning of complex automation systems •...
  • Page 22: Assembly Dimensions

    Assembly dimensions Assembly dimensions The following pages show diagrams of the Industrial PC, with dimensions in mm. The assembly of the unit must take place with the orientation diagrammed here. Warning Horizontal Installation Side View Front View Top View C6250...
  • Page 23 The assembly of the unit must take place with the orientation diagrammed here. Warning Vertical Installation Side View Front View Top View C6250...
  • Page 24: Appendix

    Appendix Appendix Technical data Dimensions Dimensions (W x H x D): 680 x 184 x 268 mm Weight: 22.2 kg (basic configuration) Do not use the PC in areas The Industrial PC may not be used in areas of explosive hazard. of explosive hazard The following conditions must be observed during operation: Environmental conditions...

This manual is also suitable for:

C6250-50

Table of Contents