Beckhoff C3620 Installation And Operating Instructions Manual
Beckhoff C3620 Installation And Operating Instructions Manual

Beckhoff C3620 Installation And Operating Instructions Manual

Build-in industrial pcs
Table of Contents

Advertisement

Quick Links

Installation- and Operating instructions for
Build-in Industrial PCs
C3620, C3640 from -0060
Version: 4.0
Date:
2020-04-24

Advertisement

Table of Contents
loading

Summary of Contents for Beckhoff C3620

  • Page 1 Installation- and Operating instructions for Build-in Industrial PCs C3620, C3640 from -0060 Version: 4.0 Date: 2020-04-24...
  • Page 3: Table Of Contents

    Delivery conditions Description of safety symbols Basic safety measures Operator's obligation to exercise diligence Operator requirements Product Description Appropriate Use Structure of the C3620 Structure of the C3640 CD/DVD-Drive (optional) Interfaces from C3620/ C3640-0060 PS/2 connections USB interfaces Network connection...
  • Page 4 Table of contents Beckhoff Support Beckhoff Service Assembly dimensions Industrial PC C3620 Industrial PC C3640 Mounting Opening Appendix Technical data Approvals FCC: Federal Communications Commission Radio Frequency Interference Statement FCC: Canadian Notice C3620, C3640...
  • Page 5: General Instructions

    All the components are supplied in particular hardware and software configurations appropriate for the application. Modifications to hardware or software configurations other than those described in the documentation are not permitted, and nullify the liability of Beckhoff Automation GmbH & Co.KG. Delivery conditions In addition, the general delivery conditions of the company Beckhoff Automation GmbH &...
  • Page 6: Description Of Safety Symbols

    This symbol is intended to highlight risks for the life or health of personnel. Danger This symbol is intended to highlight risks for equipment, materials or the environment. Warning This symbol indicates information that contributes to better understanding. Note C3620, C3640...
  • Page 7: Basic Safety Measures

    If metal objects such as screws or tools fall onto operating circuit boards. • If connecting cables internal to the PC are removed or inserted during operation. • If plug-in cards are removed or inserted when the PC is switched C3620, C3640...
  • Page 8: Operator's Obligation To Exercise Diligence

    Read the operating Every user of the Industrial PC must have read these operating instructions instructions. Software knowledge Every user must be familiar with any of the functions of the software installed on the PC that he can reach. C3620, C3640...
  • Page 9: Product Description

    Product Description Product Description Appropriate Use The C3620 and C3640 Industrial PCs are designed for mounting in control cabinets in machine and plant engineering applications. Structure of the C3620 View of the open PC C3620 7-Slot- 100-240 V ATX motherboard full range power supply 12“...
  • Page 10: Structure Of The C3640

    The connections of the Industrial PC to the outside are located on top of the housing. CD/DVD-Drive (optional) Configuration with CD/DVD-drive (optional) Optional the Industrial PC is fitted with a CD/ DVD-drive. The drive is located at the rear side of the PC. C3620, C3640...
  • Page 11: Interfaces From C3620/ C3640-0060

    The four USB interfaces (X108 – X111) are used to connect peripheral devices with USB connections: ▪ ® Devices with Intel generation processors (C3620/ C3640-0060) are equipped with 2 USB2.0 (X110, X111) and 2 USB3.0 (X108, X109) interfaces. ▪ ® Devices from Intel and 7 generation processors (C3620/ C3640-0070) are equipped with 4 USB3.0...
  • Page 12: Installation Instructions

    4. Please keep the associated paperwork. It contains important information for handling the unit. 5. Check the contents for visible shipping damage. 6. If you notice any shipping damage or inconsistencies between the contents and your order, you should notify Beckhoff Service. C3620, C3640...
  • Page 13: Installation Of The Pc In The Control Cabinet

    Installation Instructions Installation of the PC in the control cabinet The C3620 and C3640 Industrial PCs are designed for rack mounting in machine and plant engineering applications. The ambient conditions specified for operation must be observed (see the section Technical data).
  • Page 14: Power Supply Connection

    0.8 A Current carrying capacity of Output voltages from Current loading the 24 V power supply maximum the 24 V power supply unit unit +5 V 25 A -5 V +12 V 10 A -12 V 1.5 A C3620, C3640...
  • Page 15: Pin Assignment And Cable Requirements

    Pin assignment for the Function 24 V power supply unit 5 4 3 2 1 Power supply not used not used Pin assignment for connecting the power switch 1 2 3 Funktion Power-Status PC_ON 24 V Versorgungsspannung + Pol C3620, C3640...
  • Page 16: Fitting The Power Supply Cable

    4. Relieve the strain on the supply cable by fixing it in place with the cable clamp (part C) and fixing screws (part D) (see photograph below). Applying the strain relief Fix the upper part (part B) of the strain relief housing by snapping it onto the lower part. C3620, C3640...
  • Page 17: Connecting Power Supply

    The maximum load is 1.4 A (max. 2.5 A from 2016 and later). • Once the PC has been de-energized via the UPS software, the UPS output is switched to 0 V. Any connected panel is thus switched off, and total discharge of the rechargeable battery is prevented. C3620, C3640...
  • Page 18: Wiring Diagram

    Wiring according to the wiring diagram (the circuit of PC_ON and Power- Status is symbolical): Wiring diagram external switch and power supply Connection of the Battery Pack and UPS Output only in combination with integrated UPS (order option). C3620, C3640...
  • Page 19: Connecting Devices

    Fitting the Power Supply Cable) into the Industrial PC's power supply socket. Then connect it to your external 24 V power supply. If a 24 V UPS is installed, the correct type of rechargeable battery must be used. Warning C3620, C3640...
  • Page 20: Operating Instructions

    If the PC was ordered without operating system, you have to install the operating system and the driver software for any auxiliary hardware yourself. Please follow the instructions in the documentation for the operating system and the additional devices. C3620, C3640...
  • Page 21: Maintenance

    The device must be fully dismantled in order to dispose of it. The housing can be sent for metal recycling. Observe national Electronic parts such as disk drives and circuit boards must be disposed of electronics scrap in accordance with national electronics scrap regulations. regulations C3620, C3640...
  • Page 22: Troubleshooting

    Nothing happens after the Industrial No power supply to the Industrial Check power supply cable PC has been switched on Other cause Call Beckhoff Service The Industrial PC does not boot CD in drive (optional). Remove CD and press any fully...
  • Page 23: Service And Support

    Fax: +49(0)5246/963-198 e-mail: info@beckhoff.com Beckhoff Support Support offers you comprehensive technical assistance, helping you no only with the application of individual Beckhoff products, but also with other, wide-ranging services: • world-wide support • design, programming and commissioning of complex automation systems •...
  • Page 24: Assembly Dimensions

    Assembly dimensions Assembly dimensions Industrial PC C3620 The assembly of the unit must take place with the orientation diagrammed here. Warning All dimensions in mm. front view left view rear view C3620, C3640...
  • Page 25: Industrial Pc C3640

    Assembly dimensions Industrial PC C3640 The assembly of the unit must take place with the orientation diagrammed here. Warning All dimensions in mm. front view left view rear view C3620, C3640...
  • Page 26: Mounting Opening

    Assembly dimensions Mounting Opening A mounting opening according to the following diagram is required: Mounting opening for C3620 Mounting opening for C3640 C3620, C3640...
  • Page 27: Appendix

    FCC: Canadian Notice FCC Approval for Canada This equipment does not exceed the Class A limits for radiated emissions as described in the Radio Interference Regulations of the Canadian Department of Communications. C3620, C3640...

This manual is also suitable for:

C3640

Table of Contents