    Grounding of the Industrial PC.................. 29 4.3.2 Connecting cables and power supply ................ 30 Switching the industrial PC on and off ....................  31 5 Beckhoff Device Manager ........................ 32 6 Decommissioning ...........................  34 Disconnecting the power supply and cables ...................  34 Disassembly and disposal.......................  35 7 Maintenance ............................ 37...
  • Page 4 Table of contents 8 Troubleshooting ............................ 43 9 Technical data ............................ 44 10 Appendix .............................. 45 10.1 Service and support ........................ 45 10.2 Approvals ............................ 45 Version: 3.7 C6017...
  • Page 5: Notes On The Documentation

    Copyright © Beckhoff Automation GmbH & Co. KG. Publication of this document on websites other than ours is prohibited. Offenders will be held liable for the payment of damages. All rights reserved in the event of the grant of a patent, utility model or design.
  • Page 6: For Your Safety

    Exclusion of liability Beckhoff shall not be liable in the event of non-compliance with this documentation and thus the use of the devices outside the documented operating conditions. Signal words The signal words used in the documentation are classified below.
  • Page 7: Fundamental Safety Instructions

    • the operating instructions are in good condition and complete, and always available for reference at the location where the products are used. C6017 Version: 3.7...
  • Page 8: Notes On Information Security

    For your safety Notes on information security The products of Beckhoff Automation GmbH & Co. KG (Beckhoff), insofar as they can be accessed online, are equipped with security functions that support the secure operation of plants, systems, machines and networks. Despite the security functions, the creation, implementation and constant updating of a holistic security concept for the operation are necessary to protect the respective plant, system, machine and networks against cyber threats.
  • Page 9: Product Overview

    Product overview Product overview The C6017 Industrial PC is part of the series of ultra-compact industrial PCs for space-saving control cabinet installation. It is a high-performance device. This variant with further optional interfaces enables adaptation to specific applications and requirements.
  • Page 10: Structure

    Product overview Structure Fig. 1: C6017_structure - basic configuration Table 1: Legend C6017 structure Component Description Mounting plate Plate for mounting the industrial PC over the narrow sides in the control cabinet Status LEDs Status display for power, hard disk, TwinCAT Name plate...
  • Page 11: Interface Description

    Product overview Interface description In the basic configuration, the C6017 includes the following interfaces: • Power supply (X101) • Ethernet RJ45 (X102, X103) • DisplayPort (X104) • USB (X105, X106) 3.2.1 Power supply The industrial PC is supplied with a nominal voltage of 24 V. The 2x2-pin voltage socket (X101) is used for connection to the power supply and the external wiring of the industrial PC.
  • Page 12: Ethernet Rj45

    Product overview 3.2.2 Ethernet RJ45 The C6017 has two Gigabit LAN ports (X102, X103). The 100Base-T and 1000Base-T Ethernet standards enable the connection of corresponding network components and data rates of 100/1000 Mbit/s. The required speed is selected automatically. The RJ45 connection technology with twisted-pair cables is used. The maximum length of the cable connection is 100 m.
  • Page 13: Usb

    USB interfaces. The following table shows the interface assignment based on the device generation: Table 5: USB interfaces based on device generation Device generation USB interfaces C6017-0010 1x USB 2.0 (X105) 1x USB 3.0 (X106) C6017-0020 2x USB 3.0 (X105, X106) The two USB interfaces each supply up to 500 mA current and are electronically protected.
  • Page 14: Displayport

    The industrial PC has a DisplayPort (X104) that enables connection of devices with DisplayPort. It facilitates transfer of image signals. In addition, DVI signals can be transferred via an adapter. Please order it from your Beckhoff sales team, quoting order identifier C9900-Z468 adapter cable DisplayPort to DVI, 40 cm.
  • Page 15: Optional Interfaces

    The Ethernet ports are not switched. They are suitable for cycle times <= 1 ms and for distributed clock applications in EtherCAT. ® The Intel i210 (MAC/PHY) controller is used for both ports. Fig. 7: C6017_Ethernet interface pin numbering C6017 Version: 3.7...
  • Page 16: Rs232

    Request to Send Signal in Clear to Send Signal in Ring Indicator Status LEDs The industrial PC has three status LEDs: PWR, TC, HDD. They provide information on the following aspects: • the status of the power controller Version: 3.7 C6017...
  • Page 17: Pwr Led

    Bootloader is starting (start sequence is being run through) Magenta Flashing (0.5 s) S UPS capacitance test (if S UPS exists) Red/magenta Flashing Checksum error during the I2C transmission in the bootloader Cyan Flashing (2 s) contact Beckhoff Service C6017 Version: 3.7...
  • Page 18: Hdd Led

    The TC LED indicates the TwinCAT status. The colors and flashing intervals have the following meanings: Table 13: Meaning of the TC LED Color Flashing interval Meaning Green Steadily lit TwinCAT Run Mode Blue Steadily lit TwinCAT Config Mode Steadily lit TwinCAT Stop TwinCAT not started Version: 3.7 C6017...
  • Page 19: Name Plate

    Fig. 10: C6017_name plate Table 14: Legend C6017 name plate Description Manufacturer, including address Model: The last four digits indicate the device generation Serial number (BTN) Date of manufacture Mainboard Main memory...
  • Page 20: 1-Second Ups

    Fig. 11: UPS function The UPS can be controlled from the PLC with the function block FB_S_UPS_BAPI. More detailed information can be found in the Beckhoff Information System under the following link: https:// infosys.beckhoff.com/index.php?content=../content/1031/tcplclib_tc2_sups/ 27021601480747275.html&id=7167070070491500024. Version: 3.7...
  • Page 21: Commissioning

    4. Check your delivery for completeness by comparing it with your order. 5. Check the contents for visible shipping damage. 6. In case of discrepancies between the package contents and the order, or in case of transport damage, please inform Beckhoff Service (see Chapter 10.1 Service and support). C6017 Version: 3.7...
  • Page 22: Control Cabinet Installation

    Commissioning Control cabinet installation The C6017 Industrial PC is designed for mounting in control cabinets in machine and plant engineering applications. The environmental conditions specified for operation must be observed (see chapter 9 Technical data [} 44]). Using different mounting plates, you can align the cable entry based on the application requirements.
  • Page 23: Mounting Options

    Fig. 14: • Connections point upwards (A) • Connections point downwards (B) • Connections point to the right (C) • Connections point to the left (D) Fig. 14: C6017_mounting options mounting plate 2 C6017 Version: 3.7...
  • Page 24: Fig. 15: C6017_Mounting Options Mounting Plate 3

    You have the following mounting options, which are shown in Fig. • Mounting via the rear panel of the device (A) • Mounting via the top of the device (B) • Mounting via the bottom of the device (C) Fig. 15: C6017_mounting options mounting plate 3 Version: 3.7 C6017...
  • Page 25: Dimensions

    Fig. 18 gives an example of the dimensions using the mounting options via the rear of the device with mounting plate 3 with DIN rail adapter. 65,9 81,9 32,3 47,3 Fig. 18: C6017_mounting plate with DIN rail adapter C6017 Version: 3.7...
  • Page 26: Installation In The Control Cabinet

    If you want to install the industrial PC in the control cabinet with the DIN rail adapter, no preparation of the control cabinet is necessary. All you need to do is attach the device to the DIN rail using the adapter. To do this, follow the steps below as shown in Figure 20: Version: 3.7 C6017...
  • Page 27: Fig. 20 C6017_Control Cabinet Installation Din Rail Adapter

    3. Keep the device pressed upwards and also hook the upper side of the adapter into the DIN rail (C). ð You have successfully installed the industrial PC on the DIN rail. Fig. 21: C6017_DIN rail adapter mounted C6017 Version: 3.7...
  • Page 28: Connecting The Industrial Pc

    Devices connected to the industrial PC with their own power supply must have the same potential for the PE and "0 V" conductors as the industrial PC (no potential difference). 230 V 24 V Grounding busbar Fig. 22: C6017_wiring example Version: 3.7 C6017...
  • Page 29: Grounding Of The Industrial Pc

    The functional earth is necessary for the EMC of the device. The functional earthing is also established via the earthing connection between the protective conductor connection on the device and the central grounding point of the control cabinet in which the PC is installed. C6017 Version: 3.7...
  • Page 30: Connecting Cables And Power Supply

    4. Fasten the power cable to the voltage connector of the industrial PC. 5. Connect the PC to your external 24 V power supply. 6. Switch on the 24 V power supply. 7. Measure the voltage on the power supply plug of the PC. Version: 3.7 C6017...
  • Page 31: Switching The Industrial Pc On And Off

    When you switch on the industrial PC for the first time, the pre-installed operating system (optional) will be started. For any additional hardware you have connected, you have to install the drivers yourself afterwards. In addition, the Beckhoff Device Manager starts automatically. The Device Manager is a software from Beckhoff that supports you in configuring the PC.
  • Page 32: Beckhoff Device Manager

    • User name: Administrator • Password: 1 You also have the option of using the Beckhoff Device Manager to remotely configure the industrial PC via a web browser. More detailed information is available in the Beckhoff Device Manager manual. First start Beckhoff Device Manager When your industrial PC is booted for the first time, the Beckhoff Device Manager also starts automatically for the first time.
  • Page 33: Fig. 24 Beckhoff Device Manager - Start Page

    Secure passwords Strong passwords are an important prerequisite for a secure system. Beckhoff supplies the device images with standard user names and standard passwords for the operating system. It is imperative that you change these. Controllers are shipped without a password in the UEFI/BIOS setup. Beckhoff recommends assigning a password here as well.
  • Page 34: Decommissioning

    5. Make a note of the wiring of all data transmission cables if you want to restore the cabling with another device. 6. Disconnect all data transfer cables from the industrial PC. 7. Finally, disconnect the ground connection. Version: 3.7 C6017...
  • Page 35: Disassembly And Disposal

    2. Unhook the upper side of the adapter from the DIN rail (B). 3. Also unhook the lower side of the adapter from the DIN rail. ð You have successfully removed the industrial PC from the control cabinet. Fig. 26: C6017_disassembly DIN rail adapter C6017 Version: 3.7...
  • Page 36 • Electronic parts such as fans and circuit boards must be disposed of in accordance with national electronic scrap regulations. • Stick insulating tape over the poles of the CR2032 battery on the motherboard and dispose of the battery via the local battery recycling. Version: 3.7 C6017...
  • Page 37: Maintenance

    Repair Only the vendor may repair the device. If a repair should be necessary, contact Beckhoff Service (see Chapter 10.1 Service and support [} 45]). Cleaning...
  • Page 38: Table 16 Replacement Recommendations For Pc Components

    NOTE Use of incorrect spare parts The use of spare parts not ordered from Beckhoff Service can lead to unsafe and faulty operation. • Only use spare parts that you have ordered from Beckhoff Service. Beckhoff industrial PCs are manufactured from components of the highest quality and robustness. They are selected and tested for best interoperability, long-term availability and reliable function under the specified environmental conditions.
  • Page 39: Fig. 27 C6017_Access To Battery And Storage Medium

    To do this, remove the two Torx TX6 screws and remove the cover (see fig. 27). Fig. 27: C6017_access to battery and storage medium You now have access to the battery (1) and storage medium (2) (see fig. 28). Fig. 28: C6017_battery and storage medium C6017 Version: 3.7...
  • Page 40: Replacing The Battery

    It is used to supply power to the clock integrated on the motherboard. If the battery is depleted or missing, the date and time are displayed incorrectly. Replacement batteries should only be obtained from Beckhoff Service (see Chapter 10.1 Service and support).
  • Page 41 Maintenance To dispose of the battery, remove it, tape off the poles and put it in the battery disposal. C6017 Version: 3.7...
  • Page 42: Replacing The Storage Media

    If you want to exchange a storage medium according to Beckhoff's recommendation, you must copy the data from the old to the new storage medium. You can use the Beckhoff Service Tool (BST) for this purpose. The BST is a graphical backup and restore program for industrial PCs with a Windows operating system. You can create an image of your operating system and use it to back up the operating system.
  • Page 43: Troubleshooting

    Nothing happens after the Missing power supply of the Check the power supply cable Industrial PC has been switched on Industrial PC Call Beckhoff Service Other cause The Industrial PC does not boot Setup settings are incorrect Check the setup settings...
  • Page 44: Technical Data

    Technical data Technical data Table 19: Technical data Product designation C6017 Dimensions (W x H x D) 82 x 82 x 66 mm, without mounting plate Weight approx. 550 g without mounting plate approx. 610 g with mounting plate Supply voltage 20.4-30 V (24 V...
  • Page 45: Appendix

    Hülshorstweg 20 33415 Verl Germany Phone: + 49 5246/963-0 email: info@beckhoff.de The addresses of the worldwide Beckhoff branches and agencies can be found on our website at http:// www.beckhoff.com/. You will also find further documentation for Beckhoff components there. 10.2 Approvals The following table shows the approvals of the Industrial PC based on the device generation: Table 20: C6017 approvals...
  • Page 46 FCC approvals for Canada FCC: Canadian Notice This device does not exceed the class A limits for radiation, as specified by the Radio Interference Regulations of the Canadian Department of Communications. Version: 3.7 C6017...
  • Page 47 C6017_control cabinet installation DIN rail adapter ..............Fig. 21 C6017_DIN rail adapter mounted ....................Fig. 22 C6017_wiring example......................... Fig. 23 Beckhoff Device Manager - Change passwords ................Fig. 24 Beckhoff Device Manager – Start page ..................Fig. 25 C6017_positions fastening screws....................Fig. 26 C6017_disassembly DIN rail adapter...................
  • Page 48 Table 11 Meaning of the PWR LED ......................Table 12 Meaning of the HDD LED......................Table 13 Meaning of the TC LED........................ Table 14 Legend C6017 name plate......................Table 15 Mounting plate ordering options....................Table 16 Replacement recommendations for PC components..............
  • Page 50 More Information: www.beckhoff.com/C6017 Beckhoff Automation GmbH & Co. KG Hülshorstweg 20 33415 Verl Germany Phone: +49 5246 9630 info@beckhoff.com www.beckhoff.com...

Table of Contents