Mitsubishi Electric CC-Link IE-NZ2GNSS2-8D User Manual page 60

Tsn remote i/o module with safety functions
Table of Contents

Advertisement

Item
Basic module
Double input discrepancy auto recovery
parameter
setting
Input dark test pulse OFF time setting
Number of pulse output for input dark test
Fast logic pattern setting
Fast logic interlock mode setting
Basic module
Wiring selection of inputs X0 to X7
parameter (X0 to
X7)
Input response time X0 to X7
Double input discrepancy detection setting
(X0, X1) to (X6, X7)
Double input discrepancy detection time (X0,
X1) to (X6, X7)
Input dark test execution setting X0 to X7
Basic module
Wiring selection of output Y0 to Y7
parameter (Y0 to
Y7)
Output dark test execution setting Y0 to Y7
Output dark test pulse OFF time setting Y0 to
Y7
Number of pulse output for output dark test
Y0 to Y7
7 SETTINGS
58
7.2 Parameter Setting
Setting details
When double input discrepancy
occurs, set whether to keep the
abnormal point in the stop state,
or to automatically return when
the error is resolved.
Set the width of the OFF pulses
that the terminals T0 and T1
output, on a module-by-module
basis.
Set the number of OFF pulses for
input dark test diagnostic on a
module-by-module basis.
Set the logic patterns for the fast
logic function.
When the fast logic function is
enabled, set whether to perform
output point interlock when the
output is turned off.
Set the input wiring method.
To prevent malfunction of the
input signal, set the sensitivity to
react to the input signal in units of
1 point.
Set whether to detect double input
discrepancy in units of 2 points.
Set the double input discrepancy
allowed time in units of 2 points.
Set whether to perform the input
dark test function of the diagnostic
function in the safety remote I/O
module in units of 1 point.
Set the wiring selection of output
in units of 1 point.
Set whether to perform the output
dark test function of the diagnostic
function in the safety remote I/O
module in units of 1 point.
Set the width of OFF pulses used
for an output dark test in units of 1
point.
Set the number of OFF pulses for
output dark test diagnostic in units
of 1 point.
Setting range
Reference
0: Not used
Page 145 Double input
1: Used
discrepancy auto
recovery setting
0: 400s
Page 146 Input dark test
1: 1ms
pulse OFF time setting
2: 2ms
0: 1 time
Page 146 Number of
1: 2 times
pulse output for input
2: 3 times
dark test
Page 148 Fast logic
0: Not used
1: Pattern 1
pattern setting
2: Pattern 2
3: Pattern 3
4: Pattern 4
0: Enable
Page 148 Fast logic
1: Disable
interlock mode setting
0: Not used
Page 144 Wiring
1: Safety double wiring
selection of input
(NC/NC)
2: Safety single
3: General single
0: 1.0ms
Page 144 Input
1: 1.5ms
response time
2: 5ms
3: 10ms
4: 20ms
5: 50ms
6: 70ms
0: Detect
Page 145 Double input
1: Do not detect
discrepancy detection
setting
1 to 6000(10ms)
Page 145 Double input
discrepancy detection
time
0: Perform
Page 146 Input dark test
1: Do not perform
execution setting
0: Not used
Page 147 Wiring
1: Safety double wiring
selection of output
(Source/Source)
2: Safety single
0: Perform
Page 147 Output dark
1: Do not perform
test execution setting
0: 400s
Page 148 Output dark
1: 1ms
test pulse OFF time
2: 2ms
setting
0: 1 time
Page 148 Number of
1: 2 times
pulse output for output
2: 3 times
dark test