  • Page 1 Tap installation instructions Zip HydroTap G4 ® Tap installation instructions 803341UK G4 Tap installation instructions v1.02 June 2016 Page 1 of 20...
  • Page 2 Tap options The G4 series offers a range of interchangeable taps to suit the customer's needs Classic HydroTap G4 range ® These standalone taps are directly compatible with the G4 Command-Centre Arc / Cube range Elite range The mixer tap range may be used in conjunction with any of the above to provide mixed hot and cold water for sanitary use.
  • Page 3: Table Of Contents

    Index Generic installation instructions Using these instructions .........................4 Min / Max water supply pressure requirements ................4 Special tool requirements ....................... 4 Hole & tap positioning ........................5 Connections ........................... 5 Tap installation 1 - HydroTap G4 Classic and Elite taps installation ..............6 ®...
  • Page 4: Generic Installation Instructions

    Generic installation instructions Cube Arc / Cube Elite Classic All-in-One Celsius Classic Mixer taps HydroTap ® Using these instructions These instruction are provided primarily to demonstrate how to install HydroTap G4 taps and do not provided ® sufficient information to install and commission complete HydroTap G4 systems.
  • Page 5: Hole & Tap Positioning

    Position the tap such that it dispenses into the sink bowl with ample clearance for a cup or tea pot. Alternatively, the tap could be mounted away from the sink using a Zip Font, available as an accessory. (See Major components and accessories, Command-Centre Installation instructions).
  • Page 6: Hydrotap ® G4 Classic And Elite Taps Installation

    Classic and Elite HydroTap G4 installation ® Elite Classic All thread rod Stainless steel Clearance envelope Black plastic spacer spacer Red boiling pipe Spider Clear vent pipe clamp (boiling models) Blue chilled pipe (chilled models) Apply a light smearing of silicon sealant on the underside of the spacer to ensure a watertight fit.
  • Page 7 Classic and Elite HydroTap G4 installation ® Stainless steel Black washer Fit the plastic spacer stainless steel Spider clamp washer, spider clamp, and nut. 35mm hole Ø Note Feed each of the tubes and USB cable evenly in between the legs of the spider Pass the tubes and USB cable through clamp during installation.
  • Page 8: Hydrotap ® G4 Arc / Cube Installation

    Arc & Cube HydroTap G4 installation ® Arc / Cube The HydroTap Arc/Cube has a spout that may be fixed in 1 of 6 angular positions (depending on the position of the rotary control) and fixed in one of two height positions. The spout is fixed and does not swivel. To reduce the risk of scalding, Position *A should not be selected with any of the boiling water models.
  • Page 9 Arc & Cube HydroTap G4 installation ® 2.2 Height adjustment (fixed position options) 50mm 2.3 Angular adjustment (fixed position options) Right hand control Left hand control 2.4 Mounting (See hole positioning, page 5 ) Upper o-ring Base ring Cut a 35mm hole in the worktop / sink. Ø...
  • Page 10: Mixer Tap Installation

    mixer tap installation Classic Cube Upper rubber washer Lower rubber Braided washer Clearance hose x 3 envelope Washer 3.3 Vented Cut a 35mm hole in the worktop / sink. Ø assembly Ø35mm Note Make sure the tap location will allow the tap spout to drain into the sink.
  • Page 11 Mixer tap installation 3.4 Vented water connections detail , disassembled Ensure flow restrictor is White marked Male - Female fitted in the mixer tap Braided hose adaptor direction to mixer tap (supplied) Flow restrictor Cold water (supplied) Isolation valve (not supplied) Filter Incoming Connect (supplied) mains cold together T-piece water supply...
  • Page 12: All-In-One Tap 'Mains' Installation

    All-in-One 'Mains' tap installation All-in-One Clearance O-ring envelope Base block spider USB cable Base block nut Cut a 50mm hole in the worktop / sink. Ø Ø50mm Note Make sure the tap location will allow the tap spout to drain into the sink. Note All silicon tubes must be cut to size.
  • Page 13 All-in-One ‘Mains’ tap installation 4.3 Base block spider markings and silicone tube positions (viewed from underneath). Blue marking Red marking Braided hose with Braided hose with blue marking red marking Red silicone tube Blue silicone tube USB cable Clear silicone tube Installing the All-in-One 'Mains' tap 4.4 All-in-One ‘Mains’...
  • Page 14: All-In-One Tap 'Vented' Installation

    All-in-One 'Vented' tap installation All-in-One Clearance O-ring envelope Base block spider USB cable Base block nut Cut a 50mm hole in the worktop / sink. Ø Ø50mm Note Make sure the tap location will allow the tap spout to drain into the sink. Note All silicon tubes must be cut to size.
  • Page 15 All-in-One ‘Vented’ tap installation 5.3 Base block spider markings and silicone tube positions (viewed from underneath). White marking Blue marking Braided hose with Braided hose with white marking blue marking Braided hose with red marking Red silicone tube Blue silicone tube USB cable Clear silicone tube Installing the All-in-One ‘Vented’...
  • Page 16: Celsius Tap Installation

    Celsius tap installation Celsius 6.1 Dimensions Ø23 Ø23 Ø49 Ø49 Cube 6.2 Celsius connections (refer to sections the 6.3 & 6.4) • Slide upper rubber washer in place on underside of tap. • Mount tap in position on 35mm hole. Ø...
  • Page 17 Celsius tap installation 6.3 Chilled and sparkling + mixed hot & cold tap installation Celsius taps require a 35mm hole. Ø Ø35mm Note Make sure the tap location will allow the tap spout to drain into the sink. Vent Upper rubber 35mm hole Ø...
  • Page 18 Celsius tap installation 6.4 Boiling + mixed hot & cold tap installation Chilled + mixed hot & cold tap installation Celsius taps require a 35mm hole. Ø Ø35mm Note Make sure the tap location will allow the tap spout to drain into the sink. Vent Upper rubber...
  • Page 19: End Of Life Disposal

    Within each of the European Union member countries, provisions have been made for collection and recycling of unwanted electrical and electronic equipment. In order to help preserve our environment we ask that you dispose of this product correctly. Please contact Zip Customer Service on 0345 6 005 005 for advice.
  • Page 20: Contact Details

    The terms “Zip” and “HydroTap” are registered trade marks of Zip Heaters (Aust) Pty Ltd. Zip products described in this publication are manufactured under one or more of the following patents: AU675601, AU637412, AU635979, GB0422305, GB2065848, US4354049, US5103859, US5099825 and SA2006/08043. Other patents are in force and patent applications are pending.