Page 1
Filtered boiling, chilled and sparkling drinking water systems. MODEL : Tap range. (See table of contents for specific models). INSTALLATION INSTRUCTIONS TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE WWW.ZIPWATER.CO.UK...
Page 2
Celsius range *Dependant upon model purchased. INSTALLATION INSTRUCTIONS TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE WWW.ZIPWATER.CO.UK...
Section 8 - Celsius All-in-One Arc tap installation ..................25 Product information End of life disposal ............................30 Warranty ................................31 Contact details ..............................32 INSTALLATION INSTRUCTIONS TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE WWW.ZIPWATER.CO.UK...
NOTE It is recommended to use a water block device to minimise the potential for water leakage in the event of a system malfunction, please refer to the Command-Centre installation instructions for details. INSTALLATION INSTRUCTIONS TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE WWW.ZIPWATER.CO.UK...
Position the tap such that it dispenses into the sink bowl with ample clearance for a cup or tea pot. Alternatively, the tap could be mounted away from the sink using a Zip Font, available as an accessory, (call Zip on 0345 6 005 005).
Ø Ø35mm Note Make sure the tap location will allow the tap spout to drain into the sink. INSTALLATION INSTRUCTIONS TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE WWW.ZIPWATER.CO.UK...
Page 7
(supplied) orientation Male - Female adaptor (supplied) Braided hose to Command Braided hose -Centre to Command -Centre (supplied) INSTALLATION INSTRUCTIONS TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE WWW.ZIPWATER.CO.UK...
Dimples threaded extension. Plastic spring clip • Secure the tap in position with the metal washer and nut. INSTALLATION INSTRUCTIONS TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE WWW.ZIPWATER.CO.UK...
Page 9
Note Use the Tube kit fitting instructions supplied with the tap kit to connect the tap head assembly to the Command-Centre. INSTALLATION INSTRUCTIONS TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE WWW.ZIPWATER.CO.UK...
Page 10
Male - Female adaptor (supplied) Braided hose Isolation valve to Command (not supplied) Braided hose -Centre to Command -Centre (supplied) INSTALLATION INSTRUCTIONS TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE WWW.ZIPWATER.CO.UK...
• Attach the braided hoses (ensure the seals on the end of the hoses are lubricated), do not over tighten. INSTALLATION INSTRUCTIONS TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE WWW.ZIPWATER.CO.UK...
Page 12
White marked Braided hose to mixer tap Incoming mains ambient water supply Braided hose to Command -Centre inlet INSTALLATION INSTRUCTIONS TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE WWW.ZIPWATER.CO.UK...
Red marking - Hot mains supply INSTALLATION INSTRUCTIONS TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE WWW.ZIPWATER.CO.UK...
Page 14
Incoming Incoming mains ambient mains hot water supply water supply INSTALLATION INSTRUCTIONS TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE WWW.ZIPWATER.CO.UK...
• Fit the base block spider to the underside of the All-in-One tap. • Clamp in position using the base block nut. INSTALLATION INSTRUCTIONS TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE WWW.ZIPWATER.CO.UK...
Page 16
• Ensure that all tubes and hoses are firmly blue plastic pipe to- Command-Centre STILL OUT secured. white plastic pipe to- SPARKLING OUT on the Command-Centre INSTALLATION INSTRUCTIONS TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE WWW.ZIPWATER.CO.UK...
Page 17
Braided hose to Command -Centre inlet Incoming Red marked mains hot Braided hose water supply to mixer tap INSTALLATION INSTRUCTIONS TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE WWW.ZIPWATER.CO.UK...
• Fit the base block spider to the underside of the All-in-One tap. • Clamp in position using the base block nut. INSTALLATION INSTRUCTIONS TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE WWW.ZIPWATER.CO.UK...
Page 19
T-piece, as supplied, to be fitted in the cold water supply line, from the isolation valve (not supplied), to the mixer tap. INSTALLATION INSTRUCTIONS TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE WWW.ZIPWATER.CO.UK...
Page 20
White marked Braided hose to mixer tap Incoming mains ambient water supply Braided hose to Command -Centre inlet INSTALLATION INSTRUCTIONS TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE WWW.ZIPWATER.CO.UK...
Attach the USB connector to the corresponding connector from the Command-Centre. Note Make sure the tap location will allow the tap spout to drain into the sink. INSTALLATION INSTRUCTIONS TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE WWW.ZIPWATER.CO.UK...
Page 22
Brass brass nut. washer lead Chilled pipe Sparkling pipe Mains hot and cold braided hoses Disassembled Assembled INSTALLATION INSTRUCTIONS TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE WWW.ZIPWATER.CO.UK...
Page 23
Boiling (red) pipe depending on model Vent (clear) pipe (Boiling models) Mains hot and cold braided hoses Disassembled Assembled INSTALLATION INSTRUCTIONS TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE WWW.ZIPWATER.CO.UK...
Page 24
Braided hose to Command -Centre inlet Incoming Red marked mains hot Braided hose water supply to mixer tap INSTALLATION INSTRUCTIONS TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE WWW.ZIPWATER.CO.UK...
Steam Vent Outlet Chilled / Sparkling / Filtered Boiling Water Chilled Water Outlet Outlet Hot & Cold Water Outlet INSTALLATION INSTRUCTIONS TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE WWW.ZIPWATER.CO.UK...
Page 26
• Fit the large rubber and metal washers over the threaded boss (on the underside of the worktop). • Clamp in position using the brass nut. INSTALLATION INSTRUCTIONS TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE WWW.ZIPWATER.CO.UK...
Page 27
Command-Centre Command-Centre Do not over tighten the braided hoses. Ensure that all tubes and hoses are firmly secured. INSTALLATION INSTRUCTIONS TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE WWW.ZIPWATER.CO.UK...
Page 28
Command-Centre Do not over tighten the braided hoses. Ensure that all tubes and hoses are firmly secure. INSTALLATION INSTRUCTIONS TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE WWW.ZIPWATER.CO.UK...
Page 29
Braided hose to Command -Centre inlet Incoming Red marked mains hot Braided hose water supply to mixer tap INSTALLATION INSTRUCTIONS TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE WWW.ZIPWATER.CO.UK...
Within each of the European Union member countries, provisions have been made for collection and recycling of unwanted electrical and electronic equipment. In order to help preserve our environment we ask that you dispose of this product correctly. Please contact Zip Customer Service on 0345 6 005 005 for advice.
WARRANTY Refer to the Command-Centre instructions for warranty information. INSTALLATION INSTRUCTIONS TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE WWW.ZIPWATER.CO.UK...
Zip Water UK 14 Bertie Ward Way, Dereham, Norfolk NR19 1TE 0345 6 005 005 sales@zipindustries.co.uk www.zipwater.co.uk INSTALLATION INSTRUCTIONS TECHNICAL SUPPORT TEL: 0345 6 005 005 EMAIL: SERVICE@ZIPINDUSTRIES .CO.UK 803341UK V1.04 NOV 2017 - ZIP G4 TAP RANGE WWW.ZIPWATER.CO.UK...