ASSIGNMeNT OF THe TeRMINAL STRIP X2A
The relay output of the control card Pro is available in two different versions.
Material number of COMBIVERT xxF6Pxx-xxyx
PIN
X2A.14
X2A.13
X2A.15
Figure 6:
WARNING

2.4.5 Specification and connection of the analog inputs

Input type
Analog input 1
Analog input 2
Input values
DC voltage input
Current input
Common mode range V
Table 12:
24
Relay (y=0-3)
Name
- in preparation -
RLA
NO contact
RLB
NC contact
RLC
Switching contact
14
R1
13 15
Fault signalling relay
Connection of the relay output
No internal protection of the relay contacts !
Welding of the relay contacts due to prohibited overload !
► Limit the current trough the contacts to 2 A, e. g. by using a fuse
type 2A gG.
► Details see safety manual.
CM
Specification of the analog inputs AN1 and AN2
Positively driven relay (y=4, 5)
(only control by safety modul)
NO contact
- not assigned -
Switching contact
14
Positively driven relay
Non-isolated differential input
X2A.17 (AN1-), X2A.18 (AN1+)
X2A.19 (AN2-), X2A.20 (AN2+)
Current/voltage switchable
±10 V
±20 mA; 4...20 mA
-12.5...17.5 V
R1
15