Mitsubishi Electric FR-CC2-N Series Instruction Manual page 70

Converter unit
Table of Contents

Advertisement

Pr.
Pr.
group
178
T700
RDI terminal function selection
187
T709
OH terminal function selection
189
T711
RES terminal function selection
190
M400
RDB terminal function selection
191
M401
RDA terminal function selection
192
M402
IPF terminal function selection
193
M403
RSO terminal function selection
194
M404
FAN terminal function selection
195
M405
ABC1 terminal function selection
248
A006
Self power management selection
255
E700
Life alarm status display
Inrush current limit circuit life
256
E701
display
Control circuit capacitor life
257
E702
display
261
A730
Power failure stop selection
268
M022
Monitor decimal digits selection
269
E023
Parameter for manufacturer setting. Do not set.
290
M044
Monitor negative output selection
296
E410
Password lock level
297
E411
Password lock/unlock
RS-485 communication station
331
N030
number
332
N031
RS-485 communication speed
RS-485 communication stop bit
length / data length
333
N032
RS-485 communication data length 0, 1
RS-485 communication stop bit
N033
length
RS-485 communication parity
334
N034
check selection
335
N035
RS-485 communication retry count 0 to 10, 9999
RS-485 communication check time
336
N036
interval
RS-485 communication waiting
337
N037
time setting
RS-485 communication CR/LF
341
N038
selection
Communication EEPROM write
342
N001
selection
343
N080
Communication error count
503
E710
Maintenance timer 1
Maintenance timer 1 warning
504
E711
output set time
MODBUS RTU communication
539
N002
check time interval
549
N000
Protocol selection
Energization time carrying-over
563
M021
times
Control circuit temperature signal
663
M060
output level
686
E712
Maintenance timer 2
Maintenance timer 2 warning
687
E713
output set time
688
E714
Maintenance timer 3
Maintenance timer 3 warning
689
E715
output set time
Name
Setting range
7, 62, 9999
2, 8, 11, 17, 25, 26, 64, 68,
90, 94, 95, 98, 99, 102,
108, 111, 125, 126, 164,
168, 190, 194, 195, 198,
199, 206, 207, 209, 210,
214, 306, 307, 309, 310,
9999
0, 1, 2
(0 to 15)
(0 to 100%)
(0 to 100%)
0, 1, 2, 21, 22
0, 1, 9999
0, 2, 4, 6
0 to 3, 5, 6, 100 to 103,
105, 106, 9999
(0 to 5), 1000 to 9998,
9999
0 to 31 (0 to 247)
3, 6, 12, 24, 48, 96, 192,
384, 576, 768, 1152
0, 1, 10, 11
0, 1
0 to 2
0 to 999.8 s, 9999
0 to 150 ms, 9999
0 to 2
0, 1
0 (1 to 9998)
0 to 9998, 9999
0 to 999.8 s, 9999
0, 1
(0 to 65535)
0°C to 100°C
0 (1 to 9998)
0 to 9998, 9999
0 (1 to 9998)
0 to 9998, 9999
Minimum
Initial
Refer to
setting
value
page
increments
1
9999
95
1
7
95
1
62
95
1
111
90
1
11
90
1
2
90
1
209
90
1
25
90
1
99
90
1
0
97
1
0
81
1%
100%
81
1%
100%
81
1
0
99
1
9999
87
1
0
87
1
9999
79
1
9999
79
1
0
106,
1
96
106,
1
1
1
0
106
1
1
1
2
106,
1
1
106
0.1 s
0 s
106
1 ms
9999
106
1
1
106
1
0
105
1
0
119
1
0
82
1
9999
82
0.1 s
9999
119
1
0
106,
1
0
87
1°C
0°C
94
1
0
82
1
9999
82
1
0
82
1
9999
82
5. PARAMETERS
5.1 Parameter List
Customer
1
setting
2
3
4
5
6
7
119
8
119
9
10
119
119
69

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fr-cc2-n450kFr-cc2-n630k

Table of Contents