Error code
Error item
H7
Character error
H8
H9
HA
Mode error
HB
Instruction code error
HC
Data range error
HD
HE
HF
Normal (no error)
 Response time
Computer
Converter unit
Converter unit
Computer
[Formula for data transmission time]
1
Communication
speed (bps)
*1
Refer to
page
109.
*2
Communication specifications
Name
Stop bit length
Data length
With
Parity check
Without
In addition to the above, 1 start bit is necessary.
Minimum number of total bits: 9 bits
Maximum number of total bits: 12 bits
*3
Data check time
Item
Monitoring
Parameter read/write
Parameter clear / All parameter clear
Reset command
 Retry count setting (Pr.121, Pr.335)
• Set the permissible number of retries at data receive error occurrence. (Refer to
• When the data receive errors occur consecutively and the number of retries exceeds the permissible number setting, a
communication fault (PU connector communication: E.PUE, RS-485 terminal communication: E.SER) occurs and the
inverter output is shut off.
• When a data transmission error occurs while "9999" is set, the inverter does not shut off its output but outputs the Alarm
(LF) signal. To use the LF signal, set "98" (positive logic) or "198" (negative logic) in any parameter from Pr.190 to Pr.195
(Output terminal function selection) to assign the function to an output terminal.
The converter unit received an unusable character (other
than 0 to 9, A to F, and control codes).
Parameter write was attempted when the converter unit does
not perform computer link communication, when the
operation commands are not given through communication,
or during converter unit operation.
The specified instruction code does not exist.
Invalid data has been specified for parameter writing, etc.
Data sending time (refer to the following formula)
Converter unit data processing time
10 ms or more necessary
Data sending time (refer to the following formula)
Number of data characters *1
Number of bits
1 bit
2 bits
7 bits
8 bits
1 bit
0
< 12 ms
< 30 ms
< 5 s
No reply
Error description
Waiting time
Data check time
(setting
10 ms)
(depends on the
instruction code ∗3)
Time
Communication specifications
(Total number of bits) *2
Check time
page 112
5.7 (N) Communication operation parameters
Converter unit operation
The converter unit does not
accept the data sent to the
converter unit. However, the
inverter output is not shut off.
The converter unit does not
accept the data sent to the
converter unit. However, the
inverter output is not shut off.
data transmission time (s)