• Real time monitor
Refer to
page 87
• Parameter
Pr.
Register
41000 to
0 to 999
41999
1000 to
45000 to
1999
45359
• Fault history
Register
40501
40502
40503
40504
40505
40506
40507
40508
• Model information monitor
Register
44001
44002
44003
44004
44005
44006
44007
44008
44009
44010
44011
44012
44013
NOTE
• When a 32-bit parameter setting or monitor item is read and the value to be read exceeds HFFFF, HFFFF is returned.
 Pr.343 Communication error count
• The communication error occurrence count can be checked.
Parameter
343
NOTE
• The communication error count is temporarily stored in the RAM memory. The value is not stored in EEPROM, and so is
cleared to 0 when power is reset or the converter unit is reset.
128
5. PARAMETERS
5.7 (N) Communication operation parameters
for the register numbers and monitor items of the real time monitor.
Name
For details on parameter names,
refer to the parameter list
(page
68).
For details on parameter names,
refer to the parameter list
(page
68).
Definition
Fault record 1
Fault record 2
Fault record 3
Fault record 4
Fault record 5
Fault record 6
Fault record 7
Fault record 8
Definition
Model (1st and 2nd characters)
Model (3rd and 4th characters)
Model (5th and 6th characters)
Model (7th and 8th characters)
Model (9th and 10th characters)
Model (11th and 12th characters)
Model (13th and 14th characters)
Model (15th and 16th characters)
Model (17th and 18th characters)
Model (19th and 20th characters)
Capacity (1st and 2nd characters) Read
Capacity (3rd and 4th characters)
Capacity (5th and 6th characters)
Setting range
(Read-only)
Read/write
Read/write
The parameter number + +41000 is the register number.
Read/write
The parameter number + +44000 is the register number.
Read/write
Read/write
Read
Being 2 bytes in length, the data is stored as H00○○.
Read
Refer to the lowest 1 byte for the error code. (For details on
Read
error codes, refer to
Read
The fault history is batch-cleared by writing to register 40501.
Read
Set any value as data.
Read
Read
Read/write
Read
Read
Read
Read
The converter model name can be read in ASCII code.
Read
"H20" (blank code) is set for blank area.
Example) For "FR-CC2-N":
Read
H46, H52, H2D, H43, H43, H32, H2D, H4E, H20, H20...H20
Read
Read
Read
Read
The capacity in the converter unit can be read in ASCII code.
Data read is displayed in increments of 0.1 kW.
Read
"H20" (blank code) is set for blank area.
Read
Example) 450K..." 4500" (H20, H20, H34, H35, H30, H30)
Minimum setting range
1
Remarks
Remarks
page
142.)
Remarks
Initial value
0