28. STANDARD vs. AUSTRALIAN DEFAULT SETTINGS
The Australian version Charge Controller has a few default settings that diff er from the Standard ver-
sion default settings. However, there are no diff erences in performance and effi ciency between the
two versions. The Standard and Australian version can be identifi ed as follows:
OutBack
Power
Charge Controller
Standard Version
Below are a few default setting diff erences between the Standard and Australian version.
Settings
Charger
12V
24V
36V
48V
60V
Equalize
12V
24V
36V
48V
60V
Equalize Time
77
12V
OutBack
Systems
Charge Controller-AU
Standard
Absorb Float
4.4V
13.6V
28.8V 27.2V
43.2V 40.8V
57.6V 54.4V
72.0V 68.0V
Equalize Volts
14.4
28.8
43.2
57.6
72.0
01 Hours
12V
Power
Systems
Australian Version
Australian
Absorb Float
14.4V
13.8V
28.8V
27.6V
43.2V
41.4V
57.6V
55.2V
72.0V
69.0V
Equalize Volts
14.7
29.4
44.1
58.8
73.5
03 Hours