13. Advanced
The ADVANCED MENU allows fi ne-tuning of the Charge Controller operations including Snooze
periods and Maximum Power Point limits. In order of appearance, the following modes occur in
the ADVANCED Menu selections:
• Snooze Mode • Wakeup • MPPT Mode • Park Mpp • Mpp Range Limit % Voc
• Absorb Time • Rebulk Voltage • Vbatt Calibration • RTS Compensation • Auto Restart
• Aux Polarity • Reset to Defaults?
ADVANCED MENU
Snooze Mode
< .6 amp
EXIT NEXT
46
From the MAIN Menu, choose Advanced and press
the <GO> soft key.
Snoozing occurs if the recharging current does not
reach the user-selected cutoff current set point as
shown in this screen. Press the <AMP> soft key to
adjust the amp setting. Press the <NEXT> soft key
AMP
for the Wakeup Mode screen.
Amp Values
0.2
0.4
0.6
0.8
1.0
Need help?