Code
Description
Electronic inverter protection
106
activated (EIP)
107
-
108
-
109
-
110
Skew load, electrical asymmetry
111
Current asymmetry
112
Cosφ too high
113
Cosφ too low
Motor heater function activated
114
(frost protection)
Too many grinder reversals or
115
grinder reversal attempt failed
116
Grinder motor overtemperature
117
Intrusion (door opened)
Signal fault, hydrogen sulfide H2S
118
sensor
119
Signal fault, analog input AI4
Auxiliary winding fault (single
120
phase motors)
Auxiliary winding current too high
121
(single-phase motors)
Auxiliary winding current too low
122
(single-phase motors)
Start capacitor, low (single-phase
123
motors)
Run capacitor, low (single-phase
124
motors)
Signal fault, outdoor temperature
125
sensor
Signal fault, air temperature
126
sensor
Signal fault, shunt relative
127
pressure sensor
128
Strainer clogged
129
-
130
-
131
-
132
-
133
-
134
-
135
-
136
-
137
-
138
-
139
-
140
-
56
Code
Description
141
-
142
-
143
-
Motor temperature 3 (Pt100,
144
t_mo3)
Bearing temperature high (Pt100),
145
in general or top bearing
Bearing temperature high (Pt100),
146
middle bearing
Bearing temperature high (Pt100),
147
bottom bearing
Motor bearing temperature high
148
(Pt100) in drive end (DE)
Motor bearing temperature high
149
(Pt100) in non-drive end (NDE)
150
Fault (add-on) pump module
151
Fault, display (HMI)
Communication fault, add-on
152
module
153
Fault, analog output
154
Communication fault, display
155
Inrush fault
Communication fault, internal
156
frequency converter module
157
Real-time clock out of order
Hardware circuit measurement
158
fault
CIM fault (Communication
159
Interface Module)
160
Cellular modem, SIM card fault
161
Sensor supply fault, 5 V
162
Sensor supply fault, 24 V
Measurement fault, motor
163
protection
164
Signal fault, LiqTec sensor
165
Signal fault, analog input 1
166
Signal fault, analog input 2
167
Signal fault, analog input 3
168
Signal fault, pressure sensor
169
Signal fault, flow sensor
Signal fault, water-in-oil (WIO)
170
sensor
171
Signal fault, moisture sensor
Signal fault, atmospheric pressure
172
sensor
Signal fault, rotor position sensor
173
(Hall sensor)
174
Signal fault, rotor origo sensor
Signal fault, temperature sensor 2
175
(t_mo2)
Code
Description
Signal fault, temperature sensor 3
176
(t_mo3)
177
Signal fault, Smart trim gap sensor
178
Signal fault, vibration sensor
Signal fault, bearing temperature
179
sensor (Pt100), general or top
bearing
Signal fault, bearing temperature
180
sensor (Pt100), middle bearing
Signal fault, PTC sensor (short-
181
circuited)
Signal fault, bearing temperature
182
sensor (Pt100), bottom bearing
Signal fault, extra temperature
183
sensor
Signal fault, general-purpose
184
sensor
185
Unknown sensor type
186
Signal fault, power meter sensor
187
Signal fault, energy meter
188
Signal fault, user-defined sensor
189
Signal fault, level sensor
Limit exceeded, sensor 1 (for
190
example alarm level in WW
application)
Limit exceeded, sensor 2 (for
191
example high level in WW
application)
Limit exceeded, sensor 3 (for
192
example overflow level in WW
application)
Limit exceeded, sensor 4 (for
193
example low level in WW/tank
filling application)
194
Limit exceeded, sensor 5
195
Limit exceeded, sensor 6
196
Operation with reduced efficiency
197
Operation with reduced pressure
Operation with increased power
198
consumption
Process out of range (monitoring,
199
estimation, calculation, control)
200
Application alarm
201
External sensor input high
202
External sensor input low
203
Alarm on all pumps
204
Inconsistency between sensors
Level float switch sequence
205
inconsistency
206
Water shortage, level 1
207
Water leakage
208
Cavitation
209
Non-return valve fault
210
High pressure