5.6 DATA and LINK LEDs 1.2 Notes Detailed description of data parameters 6.1 Connection and assembly overview The symbols and notes below may appear in Grundfos 6.2 Control parameters, output assembly 1 installation and operating instructions, safety instructions and 6.3 Other settings service instructions.
DDA and DDA XL, referred to as ’DDA pump’ in this document. Ethernet cable type with four twisted pairs of CAT5 wires. Grundfos cannot be held responsible for any problems caused directly or indirectly by using information in this functional profile. Enhanced CAT5 cable with better CAT5e performance.
E-box (small DDA) or the CIU box (DDA XL). E-box comes with the CIM 500 module mounted inside, whereas the CIU box must have the CIM 500 module mounted upon installation. See fig. and 2.
Conductors: A, B and Y. CIU box enclosure class IP54 CIU box dimensions (H x W x D) 182 x 108 x 82 mm 4.2 CIM 500 Ethernet CIM 500 Ethernet specifications Description Comments DHCP, HTTP, Ping, FTP, SMTP, SNTP,...
• Device Level Ring (DLR) protocol (announce-based ring node) • Quality of Service (QoS) • IPv4 Address Conflict Detection (ACD) Communication watchdog with fixed 5 seconds time-out. It can be Watchdog enabled via the CIM 500 web page. Certificate Plugfest December 2018, Conformance July 2019.
5.3 Setting the IP addresses The CIM 500 Ethernet module is by default set to a fixed IP address. It is possible to change the IP address settings from the built-in webserver.
LED2 You can configure CIM 500 using the built-in webserver. To Status Description establish a connection from a PC to CIM 500 the following steps are required: CIM 500 is switched off. • Connect the PC and CIM 500 using an Ethernet cable.
6.2 Control parameters, output assembly 1 The control parameters are output parameters for controlling the digital dosing pump. All the settings and control actions represented by the EtherNet/IP control parameters below can also be done from the operating panel, unless otherwise stated. The present status of each parameter can be read from the associated Dynamic status parameter.
Page 11
RemoteAccessReq Control bits with a state event trigger behave like a "state" that is Control bit used by CIM 500 to activate control from the bus. forced upon the DDA pump. CIM 500 attempts to make the pump The pump can only be controlled via the operating panel operate according to the "requested"...
Page 12
SetAnalogMode When "Bus control" is selected via the operating panel, the EtherNet/IP watchdog is automatically enabled every time the Control bit used to select the type of the analog input signal. pump is powered on. If the bus communication is somehow 0-20 mA.
SetStopKeyOn 6.3 Other settings Control bit corresponding to pressing the start/stop button SetOutputRelays the pump. SetOutputRelay1 (parameter 14) and SetOutputRelay2 (parameter 15) are used to control the output relays 1 and 2. Value Name A relay has to be set to "Bus control" via the operating panel if it should be controllable from the bus.
6.5 Configuration parameters, Input/Output explicit messaging Configuration parameters are parameters that can be used to program selected settings of the digital dosing pump. Range/ Name Data type Scaling Description Resolution SetPressureMax SINT16, 0xC3 0.1 bar 0 - 3276.7 bar Setting the pressure max. alarm limit...
Page 16
6.6 Dynamic status parameters, input assembly 2 Dynamic status parameters are parameters that describe the actual modes and states of the digital dosing pump. They are thus variables that can often change during the operation of the digital dosing pump. This assembly is included in assembly 1.
Page 17
Range/ Name Data type Scaling Description Resolution Status of Stop from external digital input DI3. 0: Stop signal from external digital input DI3 is not 10. StopFromExternal active. 1: Stop signal from external digital input DI3 is active. Status of Stop from bus. 0: Stop command from bus is not active.
Page 18
Range/ Name Data type Scaling Description Resolution Digital Inputs Array of Bools Digital inputs 0. DI1 Status of DI1 – Level low 1. DI2 BYTE, 0xD1 Status of DI2 – Level empty Bool (state) 0, 1 2. DI3 Status of DI3 – Extern stop 3.
Page 19
6.6.1 Alarms and warnings Depends on Event Auto- Event code Event group Event description FlowControl action acknowledge enabled Service now (time for service exceeded). Warning Flow deviation (performance requirement not met). Warning Soon time for service (general service information). Warning Air bubbles, gas in pump head, deaerating problem.
Page 20
Explanation of ActualStartStop Status enumeration for reading whether the pump is started, stopped, calibrating or in service mode: Value Name Started This has the following meaning for the different operating modes: • "Manual": The pump is dosing according to ActualSetpointManual (parameter 300). •...
6.7 Static status parameters, input assembly 3 Static status parameters are parameters that describe characteristics of the digital dosing pump. They are constants whose values cannot change. This assembly is included in assembly 1. Range/ Name Data type Scaling Description Resolution UnitFamily Unit Family...
Range/ Name Data type Scaling Description Resolution Measured absolute pressure. The SetFlowControlEnable bit (parameter 10) must be set for this value to be available. MeasuredPressure 0.1 bar 0 - 3276.7 bar Except for the atmospheric pressure, it corresponds to the “Backpressure” reading SINT16, 0xC3 on the display.
You can detect faults in a module by observing the status of the two status LEDs. See the table below. CIM 500 fitted in a Grundfos booster system or CIM 500 fitted in a CIU 500 Ensure that SW1 is in position "3".
Page 24
10. Grundfos alarm and warning codes This is a complete list of alarm and warning codes for Grundfos products. For the codes supported by this product, see the alarms and warnings section. Code Description Code Description Code Description Motor temperature 2 (Pt100,...
Page 25
Code Description Code Description Code Description Electronic inverter protection Signal fault, temperature sensor 3 activated (EIP) (t_mo3) Signal fault, Smart trim gap sensor Signal fault, vibration sensor Signal fault, bearing temperature Motor temperature 3 (Pt100, sensor (Pt100), general or top t_mo3) bearing Bearing temperature high (Pt100),...
Page 26
Code Description Code Description Code Description Low pressure Communication fault, I/O module Motor phase failure Diaphragm tank precharge Automatic motor model recognition Combi event pressure out of range failed Motor relay has been forced VFD not ready Night flow max. limit exceeded (manually operated or commanded) Water shortage, level 2...
Page 27
1. Webserver configuration The built-in webserver offers easy monitoring of the CIM 500 module, and makes it possible to configure the selected Industrial Ethernet protocol. Using the webserver, you can also update the firmware of the CIM 500 module and store or restore...
Page 28
• at least one upper case letter • at least one numeric or special character. When logging you have four attempts before a back-off algorithm starts an exponentially increasing time delay between each attempt. Power cycling CIM 500 resets the back-off algorithm.
Page 29
Configuration of the subnet mask if a DHCP server is not used. Gateway Configuration of the gateway address if a DHCP server is not used. The CIM 500 module can be configured to automatically obtain its EtherNet/IP network settings from a DHCP Use DHCP server, if available on the network.
Page 30
1.5 Network settings This web page is used to configure the network settings of the webserver and of the GENIpro TCP protocol. The network settings here are also used for BACnet IP. Additional configuration of BACnet IP is done in the Real Time Ethernet Protocol menu. See EtherNet/IP configuration.
Page 31
1.6 User Management A login is required for any change of the CIM 500 settings, and this web page is used to configure the username and password. See Login. It is only possible to configure one user. Fig. 5 User management...
Page 32
1.7 Update You can update the firmware by means of the built-in webserver. The binary file is supplied by Grundfos. To make installation and configuration easier, you can upload the configuration to a PC for backup or distribution to multiple modules.
Page 33