9.16 Event log register block

The event log contains the latest 40 event entries. Each entry
consists of seven registers, containing information about the
event.
Address
Register name
06001
NoOfEventsInLog
06002
EventIDLog1
06003
EventCodeLog1
06004
EventSourceLog1
06005
EventDeviceNo
06006
EventTypeAndConditionLog1
06007
EventTimeStampLog1HI
06008
EventTimeStampLog1LO
06009-06274 Event log 2...39
06275
EventIDLog40
06276
EventCodeLog40
06277
EventSourceLog40
06278
EventDeviceNo
06279
EventTypeAndConditionLog40
06280
EventTimeStampLog40HI
06281
EventTimeStampLog40LO

9.17 Reading the event log

The event log has a size of 282 registers containing the latest 40
alarm and warning events. The number of contained event logs
can be read from NoOfEventsInLog (register 06001).
Each event is represented as an event record of seven registers:
EventID
EventCode
EventSource
EventDeviceNo
EventTypeAndCondition
EventTimeStampHI
EventTimeStampLO.
The EventID is a unique "tag" for the event record. These IDs are
incremented successively corresponding to the succession of the
events they represent. The event log can be handled in three
ways:
Reading the complete log, all 40 event records, regularly and
afterwards sorting "new" ones from "old" ones.
Reading the event ID of the latest record (EventLogLatestID,
register 00216) and comparing it with the event ID of the
previously read record to see how many "new" records are
generated. Then afterwards reading only the "new" ones.
Clearing the event log with Control.ResetEventLog (register
00101, bit 2) after it is read. Then afterwards the event log will
contain "new" events only.
The CIM module ensures that logged data are
protected against internal updates during the time
they are accessed from Modbus, so that the event
log constitutes a time-consistent block (data
coherency).
Scale
Description
Unscaled
Number of events in the event log.
Unscaled
Event ID for logged event No 1.
enum
Event code for logged event No 1.
Event source for logged event No 1.
enum
0: System
6: Pump.
Device number related to the event or its recognition.
0: No related number
Unscaled
1: Value of related number, pump 1
2: Value of related number, pump 2.
Event type and condition of logged event No 1.
0. -
1: Alarm condition appears
enum
2: Alarm condition disappears
3: Warning condition appears
4: Warning condition disappears.
1 second
Seconds since midnight 1 January 1970 (UNIX time).
-
-
Unscaled
Event ID for logged event No 40.
enum
Event code for logged event No 40.
enum
Event source for logged event No 40.
Unscaled
Device number related to the event or its recognition.
enum
Event type and condition of logged event No 40.
1 second
Seconds since midnight 1 January 1970 (UNIX time).
33