Phantom-S Product Back Interface - Pylontech Phantom-S Product Manual

Lithium-ion phosphate battery
Hide thumbs Also See for Phantom-S:
Table of Contents

Advertisement

PHANTOM Product Back Interface
+ Power Terminal
Power Switch
Power Switch: BMS standby, no power output
RUN
RUN LED: to show the Power Switch is ON, and the equipment has electricity.
ADD Switch (5)
ADD Switch: 4 ADD switches, Dip1 to definite different baud rate (0 is 115200, 1 is
9600). Nether position is OFF, means "0". Upper position is ON, means "1". "0000"
setup the baud rate 115200, and "1000" setup the baud rate 9600. The settings will
be active only after restart the battery.
The slave battery's address will be assigned automatically. 1 master battery can supervise 7 slave
batteries (maximum 8 batteries in each battery group). Multiple battery group should setup the master
batteries' ADD switch. (Refer to Chapter 4 / D)
Dip2
Dip3
Dip4
0
0
1
0
0
1
1
1
0
0
1
0
0
1
1
1
Console
Console Communication Terminal: (RJ11 port) follow RS232 protocol, for manufacturer or professional
engineer to debug or service.
- Power Terminal
0
0
: Single battery group's master battery should setup as this.
th
0
1
: 1
battery group's master battery should setup as this.
st
st
0
2
: 2
battery group's master battery should setup as this.
nd
nd
0
3
: 3
battery group's master battery should setup as this.
rd
rd
1
4
: 4
battery group's master battery should setup as this.
th
th
1
5
: 5
battery group's master battery should setup as this.
th
th
1
6
: 6
battery group's master battery should setup as this.
th
th
1
7
: 7
battery group's master battery should setup as this.
th
th
Dry Contact Terminal
Link Port 0/1
CAN/RS485
Group Address Number
6/23
ON/Off Led
Power
Console
ADD
Switch
19PISV0606
Grounding
Point
ON
OFF