Bms Function - Pylontech Phantom-S Product Manual

Lithium-ion phosphate battery
Hide thumbs Also See for Phantom-S:
Table of Contents

Advertisement

Power Terminals
Power cable terminals: there are two pair of terminals with same function, one
connect to equipment, the other one paralleling to other battery module for
capacity expanding. For each single module, each terminal can achieve charging
and discharging function. For power cables uses water-proofed connectors. It must
keep pressing this Lock Button before pulling out the power plug.
Dry Contact Terminal
Dry Contact Terminal: provided 1 way input and 3 ways output dry contact signal.

BMS function

Protection and Alarm
Charge/Discharge End
Charge Over Voltage
Charge/Discharge Over Current
High/Low Temperature
Short Circuit
Power Cable Reverse
Management and Monitor
Cells Balance
Intelligent Charge Model
Capacity Retention Calculate
Administrator Monitor
Operation Record
8/23
Lock
Button
19PISV0606