Advanced Diagnostics Configuration
November 2019
9.12.1
Test scope
Continuous Smart Meter Verification can be configured to monitor the sensor coils,
electrodes, and transmitter calibration, All of these parameters can be individually enabled
or disabled. These parameters apply to continuous Smart Meter Verification only.
Coils
LOI menu path
Continuously monitor the sensor coil circuit by enabling this continuous Smart Meter
Verification parameter.
Electrodes
LOI menu path
Continuously monitor the electrode resistance by enabling this continuous Smart Meter
Verification parameter.
Transmitter
LOI menu path
Continuously monitor the transmitter calibration by enabling this continuous Smart Meter
Verification parameter.
Analog output
LOI menu path
Continuously monitor the analog output signal by enabling this continuous Smart Meter
Verification parameter.
9.13

Smart Meter Verification test results

If the Smart Meter Verification test is initiated by command, the transmitter will make
several measurements to verify the transmitter calibration, sensor calibration, coil circuit
health, and electrode circuits health. The results of these tests can be reviewed and
recorded on the
form and enter the test results as you view them. The completed form can be used to
validate that the meter is within the required calibration limits to comply with
governmental regulatory agencies.
Depending on the method used to view the results, they will be displayed in either a menu
structure, as a method, or in the report format. When using the LOI, the parameters are
viewed as a method using the left arrow key to cycle through the results.
102
Diagnostics → Diag Controls → Cont Meter Ver → Coils
Diagnostics → Diag Controls → Cont Meter Ver → Electrodes
Diagnostics → Diag Controls → Cont Meter Ver → Transmitter
Diagnostics → Diag Controls → Cont Meter Ver → Analog
Output
Table 9-2
form. Print the "Commanded Calibration Verification Results"
®
Rosemount
8782 Slurry Magnetic Flow Meter Transmitter with HART Protocol
Reference Manual
00809-0100-8782