Emerson Rosemount 8782 Reference Manual page 62

Slurry magnetic flow meter transmitter with hart protocol
Hide thumbs Also See for Rosemount 8782:
Table of Contents

Advertisement

Operation
November 2019
Totalizer
Control
Diagnostics
Basic Config The basic config buttons provide direct access to the most common
62
The totalizer control buttons enable you to view, start, stop, read, and
reset the totalizer.
—VIEW TOTAL. Scroll through the totalizer values in aphabetical
order (Totalizer A, Totalizer B, Totalizer C).
—START/READ. This functionality applies to the currently displayed
totalizer value.
If the totalizers are not running, pressing this button starts ALL
totalizers counting.
If the totalizers are running, pressing this button pauses the display,
enabling the user to read the total value. It does NOT stop the
totalizer value from accumulating in the background. Pressing the
button while the display is paused returns the display to the
accumulating totalizer value
—STOP/RESET. This functionality applies to the currently displayed
totalizer value.
If the totalizers are running, pressing this button stops ALL totalizers
from accumulating.
If the totalizer is stopped, pressing this button resets the total value to
a value of zero.
Note
If you attempt to reset the totalizer from the LOI when it is configured
as non-resetable from the LOI, a notification appears.
The diagnostics buttons provide direct access to the advanced diagnostic
functions of the transmitter and meter verification.
—ADV DIAG. Access the advanced diagnostic menu.
—METER VERIFY. Run Meter Verification.
transmitter parameters.
—SENSOR CAL NO. Access the sensor calibration number
parameter. Press , , and
Press
to store the new value as the sensor calibration number.
—SENSOR SIZE. Access the Line Size parameter. Press
select the sensor line size. Press
store the new value as the sensor line size.
®
Rosemount
8782 Slurry Magnetic Flow Meter Transmitter with HART Protocol
to modify the sensor calibration number.
to increment the line size. Press
Reference Manual
00809-0100-8782
or
to
to