Stow & Deploy Positions - RESEARCH CONCEPTS RC4000 User Manual

Antenna controller boardset
Hide thumbs Also See for RC4000:
Table of Contents

Advertisement

RC4000 ACU Boardset
3.3.1.3.10 Stow & Deploy Positions
The STOW & DEPLOY group allows the user to change the target positions for STOW and DEPLOY
movements.
AZ_STW:
EL_STW: -67.5 EL_DEP:
PL_STW:
AZIMUTH STOW <-180.0/180.0>
AZ_STW:
EL_STW:
PL_STW:
These items define the STOW position.
AZ_DEP:
EL_DEP:
PL_DEP:
These items define the DEPLOY position.
SNUG:
On certain mounts there needs to be a delay between the time that the elevation stow limit is sensed and
when the elevation motor is deenergized. For mounts where this is not the case, this item is ignored by
setting to 0.0 seconds.
PL_MOVE:
This item defines whether or not the polarization axis is moved during a STOW and/or DEPLOY.
0 – the polarization axis will not be moved as part of either STOW or DEPLOY
1 – polarization will move to the PL_STW position as part of STOW (no DEPLOY movement)
2 – polarization will move to the PL_DEP position as part of DEPLOY (no STOW movement)
3 – polarization will move during both STOW and DEPLOY
NOTE: the default value is to have polarization move during DEPLOY to be consistent with earlier
versions of the software. Default STOW movement is per mount type.
0.0 AZ_DEP:
17.3
0.0 PL_DEP:
AZIMUTH STOW <-180.0/180.0>
ELEVATION STOW <-90.0/120.0>
POL STOW <-180.0/180.0>
AZIMUTH DEPLOY<-180.0/180.0>
ELEVATION DEPLOY <-90.0/90.0>
POL DEPLOY <-180.0/180.0>
ELEV STOW DELAY TIME <0.0-10.0 SECS>
POL MOVE<0-NONE 1-STOW 2-DEPLOY 3-BOTH>
126
Chapter 3
0.0
CONFIG-STOW
SNUG: 0.0
0.0
PL_MOVE:0
Software