Stow & Deploy Positions - RESEARCH CONCEPTS RC3000 User Manual

Mobile antenna controller
Table of Contents

Advertisement

RC3000 Antenna Controller
3.3.1.3.10 Stow & Deploy Positions
The STOW & DEPLOY group allows the user to change the target positions for STOW and DEPLOY
movements.
AZ_STW:
EL_STW: -67.5
PL STW:
AZIMUTH STOW <-180.0/180.0>
AZ_STW:
EL_STW:
PL_STW:
These items define the STOW position.
AZ_DEP:
EL_DEP:
PL_DEP:
These items define the DEPLOY position.
PL_ENABLE:
This item defines whether or not the polarization axis is moved during a STOW and/or DEPLOY.
0 – the polarization axis will not be moved as part of either STOW or DEPLOY
1 – polarization will move to the PL STW position as part of STOW (no DEPLOY movement)
2 – polarization will move to the PL DEP position as part of DEPLOY (no STOW movement)
3 – polarization will move during both STOW and DEPLOY
NOTE: the default value is to have polarization move during DEPLOY to be consistent with earlier
versions of the software. Default STOW movement is per mount.
EL_TIME:
On certain mounts there needs to be a delay between the time that the elevation stow limit is sensed and
when the elevation motor is deenergized. For mounts where this is not the case, this item is ignored.
0.0
AZ_DEP:
EL DEP:
0.0
PL_DEP:
AZIMUTH STOW <-180.0/180.0>
ELEVATION STOW <-90.0/90.0>
POL STOW <-180.0/180.>
AZIMUTH DEPLOY<-180.0/180.0>
ELEVATION DEPLOY <-90.0/90.0>
POL DEPLOY <-180.0/180.0>
POL MOVE <0-NONE 1-STOW 2-DEPLOY 3-BOTH>
ELEV STOW TIMER<0-DISABLE, 1-99 SECONDS>
116
Chapter 3
0.0 CONFIG-STOW
22.3 EL_TIME: 0
0.0 PL_ENABLE:0
Detailed Operation

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rc3000aRc3000b

Table of Contents