RC4000 ACU Boardset
POL STOW & DEPLOY
The POL STOW & DEPLOY group allows the user to change the target positions for STOW and DEPLOY
movements for the polarization axis.
POL#:0
PL_STW:
<SCR> THRU LIST, <ENTER> TO MODIFY DATA
PL_STW:
These items define the STOW position.
PL_DEP:
These items define the DEPLOY position.
PL_MOVE:
This item defines whether or not the polarization axis is moved during a STOW and/or DEPLOY.
0 – the polarization axis will not be moved as part of either STOW or DEPLOY
1 – polarization will move to the PL_STW position as part of STOW (no DEPLOY movement)
2 – polarization will move to the PL_DEP position as part of DEPLOY (no STOW movement)
3 – polarization will move during both STOW and DEPLOY
NOTE: the default value is to have polarization move during DEPLOY to be consistent with earlier
versions of the software. Default STOW movement is per mount type.
0.0 PL_DEP:
POL STOW <-180.0/180.0>
POL DEPLOY <-180.0/180.0>
POL MOVE<0-NONE 1-STOW 2-DEPLOY 3-BOTH>
128
Chapter 3
CONFIG-STOW
0.0
PL_MOVE:3
Software