RC4000 ACU Boardset

3.3.1.3.6 Elevation Count Movement

FAST/SLOW: 50 COAST:
MAX ERROR: 2
FAST/SLOW THRESHOLD <0 – 999 PULSES>
FST/SLW:
FAST/SLOW THRESHOLD <0 - 999 PULSES>
During an automatic move, the elev_fast_slow_pulse_threshold configuration item is used to set the
number of pulses before a target position is reached when the controller switches the speed of the drive
from fast to slow.
COAST:
COAST RANGE <0 - 999 PULSES>
During an automatic move, the elev_coast_pulse_threshold configuration item sets the number of pulses
before the target position is reached where the drive will be deactivated. The idea is to deactivate the
drive and let the antenna coast into position. If prior to the initiation of the move operation, the total
number of degrees that the actuator has to move to reach the target position is less than the 'Coast
Threshold, the drive will be deactivated when its position is within 'Max Error of the target position.
MAX ERR:
MAXIMUM ERROR <0 - 10 PULSES>
The elev_max_position_pulse_error configuration item sets the maximum acceptable error between the
final resting position and a target position during an automatic move.
TRIES:
MAX NUMBER OF TRIES <0 - 10>
The elev_auto_move_max_retry_pulse_cnt configuration item sets the maximum number of attempts
which will be made to hit a target position (within Max Error - described above) during an automatic
move based on potentiometer feedback.
Chapter 3
CONFIG_EL COUNT
4
TRIES: 3