Alarm
Low Battery
Invalid Date/Time
Limits Inactive
Local Jog Connected

3.1.1.2 Azimuth

Warning
Description/Recommended Action
CCW, ccw
Antenna is at the azimuth hardware limit (CCW) or azimuth software limit (ccw), move
the antenna azimuth CW out of the limit.
CW, cw
Antenna is at the azimuth hardware limit (CCW) or azimuth software limit (ccw), move
the antenna azimuth CCW out of the limit.
STOW, stow
Antenna is at the azimuth hardware limit (STOW) or azimuth software limit (stow), this
is part of normal operation.

3.1.1.3 Elevation

Warning
Description/Recommended Action
DOWN,
Antenna is at the elevation hardware limit (DOWN) or azimuth software limit (down),
down
move the antenna elevation up out of the limit.
UP, up
Antenna is at the elevation hardware limit (UP) or elevation software limit (up), move
the antenna elevation down out of the limit.
STOW, stow
Antenna is at the elevation hardware limit (STOW) or elevation software limit (stow),
this is part of normal operation.
Chapter 5

3 SUPPORT

Description/Recommended Action
Battery used to backup NVRAM and Date/Time is low. Replace internal
battery backup.
Date/Time is corrupt. Reset the Date/Time via maintenance or GPS time
sync.
The software limits of the controller are currently disabled. Reactivate
limits via Limits maintenance screen.
A local jog panel or handheld remote front panel is currently connected to
the ACU. Disconnect the local jog panel or handheld remote front panel.