ADIC Scalar 1000 User Manual page 81

For the scalar 1000 and 10k
Hide thumbs Also See for Scalar 1000:
Table of Contents

Advertisement

Step 20.
Step 21.
Example:
SN60023 > ping "192.168.1.1", 10
PING 192.168.1.1: 56 data bytes
64 bytes from 192.168.1.1: icmp_seq=0. time=0. ms
64 bytes from 192.168.1.1: icmp_seq=0. time=0. ms
64 bytes from 192.168.1.1: icmp_seq=0. time=0. ms
64 bytes from 192.168.1.1: icmp_seq=0. time=0. ms
64 bytes from 192.168.1.1: icmp_seq=0. time=0. ms
64 bytes from 192.168.1.1: icmp_seq=0. time=0. ms
64 bytes from 192.168.1.1: icmp_seq=0. time=0. ms
64 bytes from 192.168.1.1: icmp_seq=0. time=0. ms
64 bytes from 192.168.1.1: icmp_seq=0. time=0. ms
64 bytes from 192.168.1.1: icmp_seq=0. time=0. ms
----192.168.1.1 PING Statistics----
10 packets transmitted, 10 packets received, 0% packet loss
round-trip (ms) min/avg/max = 0/0/0
value = 0 = 0x0
Display of failed PING test:
Example:
SN60023 > ping "192.168.1.251",10
PING 192.168.1.251: 56 data bytes
request timed out
value = -1 = 0xfffffff
Step 22.
6-00020-02
SNC 5100
From the service terminal, enter the
the SNC 5100 to finish booting.
Go back to step 14.
Enter the command
ping " <host IP address> " ,
is four decimal numbers separated by periods.
IP address>
<host IP address>
administrator for PING testing.
Display of successful PING test:
If the PING test passes, go to step 23.
If the PING test fails, inform the system administrator that there is a
network hardware problem where the SNC 5100 is attached.
Exit this MAP.
reboot
is the address provided by the network
command and wait for
where
<host
Ethernet MAP
73