ADIC Scalar 1000 User Manual page 134

For the scalar 1000 and 10k
Hide thumbs Also See for Scalar 1000:
Table of Contents

Advertisement

fcPortModeSet [port],[mode]
The
fcPortModeSet
port. See also the
The default port mode is Public Target. Consequently, if attached to a Fabric
device the SNC 5100 will register as a Target with the name server. If the port
mode is Private Target, the SNC 5100 does not register with the name server
and the Fabric device will not recognize the SNC 5100 as a Target.
The port must be in Initiator mode if you want the SNC 5100 to scan for target
devices on the port. When the port is in Private Initiator mode, the SNC 5100
only scans for devices on the local loop. If the port mode is in Public Initiator
mode, the SNC 5100 also scans for devices attached to a Fabric.
Parameter
Port
Mode
SN60023 > fcPortModeSet 1,2
value = 0 = 0x0
SN60023 >
fcRestart [port]
The
fcRestart
126
Commands
SNC 5100
command sets the mode for the specified Fibre Channel
fcPortModeGet
Value
1
The SNC 5100 connection labeled FC1
2
The SNC 5100 connection labeled FC2
1
Private Target
2
Private Initiator
3
Private Target and Initiator
17
Public Target
18
Public Initiator
19
Public Target and Initiator
Caution
You must issue the
fcRestart
for the new setting to take effect. See the
further information.
command restarts the specified Fibre Channel port. You
command.
Meaning
command or reboot the SNC 5100
fcRestart
command for