ADIC Scalar 1000 User Manual page 172

For the scalar 1000 and 10k
Hide thumbs Also See for Scalar 1000:
Table of Contents

Advertisement

SN60023 > setNettime 1
Nettime 1 value = 0 = 0x0
setSnaCCLun [newLUN]
The
setSnaCCLun
LUN to the specified value.
newLUN is the new value for the Command and Control LUN. Valid values
are 0 through 127.
The new setting takes effect immediately. The previous value is removed from
the device map and database and a trap is generated indicating that the device
was removed.
If the new LUN is not currently in use, a new entry is added in the device map
and database. A trap will be generated indicating the new device was added.
If the new LUN is already in use, the Command and Control LUN will be
disabled. It will remain disabled until the device mapped at the requested LUN
is removed and deleted from the database. In this case, you can use the
mapRebuildDatabase
and to allow the new Command and Control LUN to be enabled.
setTimeHost
The
setTimeHost
system. The "
add a host named Cronos to the system enter the following command:
SN60023 > setTimeHost "Cronos"
Time Host Cronos value = 0 = 0x0
SN60023 >
sfmAccessApply
The
sfmAccessApply
and stored in memory to take effect immediately and also saves them to the
SFM database.
164
Commands
SNC 5100
command reassigns the SNC 5100's Command and Control
command to remove the previous LUN assignment
Caution
Because AIX and NT use LUN 0 when they issue a Report LUNs
command, you must make sure that a device is configured at LUN
0.
command adds a host running timeserver to the SNC 5100
" command must already have been issued. To
setNettime 1
command causes the settings that have been changed
6-00020-02

Advertisement

Table of Contents
loading

This manual is also suitable for:

Scalar 10kSnc 5100

Table of Contents