The local Real Time Clock can also be synchronized with a remote timeserver
See the
rtcSetCurrent
SN60023 > date
SN60023 > THU JAN 25 20:32:49 2001
SN60023 >
dateSetFromRTC
The
dateSetFromRTC
the date display. Use the
SN60023 > dateSetFromRTC
value = 0 = 0x0
SN60023 >
diagBoot
This command is used only to transition the SNC 5100 from normal operation
to the special diagnostic mode. The
ffs:mt directory exists. It verifies that the files diagnstk.o and diagnstk.rc are in
the flash file system. If they are in the root directory, it moves them to the ffs:mt
directory.
It copies the existing bootline to a file in the ffs:mt directory on the SNC 5100
and installs a new bootline directing the SNC 5100 to boot using a special
diagnostic startup script ffs:mt/diagnstk.rc. It renames the persistent map file
config/device.map as config/device.bak (a new file will be generated after
rebooting).
Finally,
diagBoot
diagHelp
The
diagHelp
SN60023 > diagHelp
** Diagnostic commands: Available in Diagnostic Mode Only **
elTest
fcSlotTest <portnum> Test specified Fibre Channel port
116
Commands
SNC 5100
command.
command sets the SNC 5100's RTC as the source of
command to display the date and time.
date
issues a reboot command to put the changes into effect
Caution
After completing use of the diagnostic commands, use the
command to restore your system to normal operation.
normalBoot
command displays a list of the diagnostic commands.
Test Ethernet port w/loop-back cable
command first ensures that the
diagBoot