6. Connect to Adjustable Skyhook Anchor with complete and compatible PFAS.
7. Adjustable Skyhook Anchor is rated for loading in any direction provided it is installed as prescribed. Suitable
for use in HLL applications.
Adjustable Skyhook Anchors must be properly flashed when used in permanent applications. It is the
responsibility of the installer/roofer to properly flash this anchor.
Maintenance, Cleaning, and Storage
If Adjustable Skyhook Anchor fails inspection in any way, immediately remove it from service, and contact
Guardian to inquire about its return or repair. Field serviceability testing is not required, and should not be
done by the end user.
Cleaning after use is important for maintaining the safety and longevity of Adjustable Skyhook Anchor.
Remove all dirt, corrosives, and contaminants from Adjustable Skyhook Anchor before and after each use. If
Adjustable Skyhook Anchor cannot be cleaned with plain water, use mild soap and water, then rinse and
wipe dry. NEVER clean Adjustable Skyhook Anchor with corrosive substances.
When not in use, store equipment where it will not be affected by heat, light, excessive moisture, chemicals,
or other degrading elements.
Inspection
Prior to EACH use, inspect Adjustable Skyhook Anchor for deficiencies, including, but not limited to, corrosion,
deformation, pits, burrs, rough surfaces, sharp edges, cracking, rust, paint buildup, excessive heating,
alteration, and missing or illegible labels. IMMEDIATELY remove Adjustable Skyhook Anchor from service if
defects or damage are found, or if exposed to forces of fall arrest.
Ensure that applicable work area is free of all damage, including, but not limited to, debris, rot, rust, decay,
cracking, and hazardous materials. Ensure that selected work area will support the application-specific
minimum loads set forth in this instruction manual. Work area MUST be stable.
At least every 12 months, a Competent Person other than the user must inspect Adjustable Skyhook Anchor.
Competent Person inspections MUST be recorded in inspection log in instruction manual and on
equipment inspection grid label. The Competent Person must sign their initials in the box
corresponding to the month and year the inspection took place.
During inspection, consider all applications and hazards Adjustable Skyhook Anchor have been subjected to.