If You Do Not Succeed In Starting The Engine; Ignition System Failure Signalization; Coolant Heater - Zetor PROXIMA GP Series Operator's Manual

Hide thumbs Also See for PROXIMA GP Series:
Table of Contents

Advertisement

OPERATION

If you do not succeed in starting the engine

Return the key to '0' position. Wait 60 second and repeat
the start.
Never help the stopping engine by a starter.
You are being exposed to the danger of starter
damage.
PCLPN038

Ignition system failure signalization

A failure of the glowing system is indicated by flashing of
the glowing signal lamp (3) and simultaneous activation of
the red (1) or orange (2) signal lamp. The failure code is
displayed in the screen.
- If the engine is at standstill, the glowing signal lamp
flashes once a second and the signal lamp (2) glows,
glowing in the emergency mode is performed similarly as
at low temperatures regardless the temperature of the
cooling liquid.
- If the engine is at standstill, the glowing signal lamp
flashes twice a second and the signal lamp (2) glows, the
glowing is turned off (not functioning).
- If the engine is running, the glowing signal lamp glows
permanently and the signal lamp (1) glows, there is
P18N056
a failure of the glowing control and glowing was not
finished. The failure must be immediately eliminated since
there is a danger that the accumulator will be discharged.

*Coolant heater

Is mounted on the right side of engine block.
output 1,000 W
voltage 230 V
PGPPN136
76

Advertisement

Table of Contents
loading

This manual is also suitable for:

Proxima gp 80Proxima gp 90Proxima gp 100Proxima gp 110

Table of Contents