If Engine Does Not Start; Ignition System Failure Signalization; Manipulation With Starter; Immediately After Start - Zetor Proxima GP Series Operator's Manual

Hide thumbs Also See for Proxima GP Series:
Table of Contents

Advertisement

If engine does not start

Return the key to position '0', wait 30 seconds and repeat
the start.
A maximum of 6 starting cycles is allowed (15 seconds
start and 30 seconds interruption is one cycle). Another
engine start is allowed after the starter cools off to
surrounding temperature.
Never help a stopping tractor with a starter.
There is a danger of starter damage.

Ignition system failure signalization

Ignition system failure is signalized by ignition control
blinking.
- If ignition control is blinking with engine at standstill once
in a second, ignition in emergency mode occurs as with
low temperatures regardless of the temperature of
coolant.
- If ignition control is blinking twice in a second with engine
at standstill, ignition is not working.
- If ignition control is blinking permanently with engine
running, there is a failure of ignition regulator and ignition
has not been completed. Failure must be removed
forthwith, since there is the danger of accumulator
depletion.

Manipulation with starter

It is forbidden to start by short circuiting starter
clamps! Tractor is started only from driver's seat!
With any manipulation or starter repair it is necessary
to disconnect minus battery pole and all shifting
levers including PTO shaft shifting lever must be in
neutral position!
Starter contacts are covered with a cap.

Immediately after start

After starting, set revolutions to 800 - 1,000 rpm
and let engine run without load for a period of app.
2 minutes.
Check greasing, charging and other functions ensuring
proper engine operation (controls must go out) in this time.
The time of engine operation without load must be
observed, in particular in winter period.