5.8. Applying silicone
Silicone prevents water from entering the gap between two joining roof plates.
Apply silicone where two transport units have been joined
(Fig. 5-3). Gaps within a transport unit are factory-sealed.
Figure 5-3 Applying silicone
5.9. Installing roof joints
Install the roof joints across shipping splits at the following locations:
–
Marine drives: at the front of the roof (the back is reserved for roof
attachments, see "5.11 Installing roof attachments" on page 78.)
–
Standard drives: at the front and the back of the roof
For the exact number and fitting location of roof joints, see "Appendix C -
Mechanical drawings".
Table 5-1 Installation material per roof joint
Items
Connecting piece
Hex-head bolt
Washer
Figure 5-4 Roof joint
PRODUCT
ACS5000W
Details
8 x 80 x 220 mm
M16 x 40
17x30x3
DOCUMENT KIND
User manual
ID Number
3BHB011552R0001
NB 312350P0464
9ABA450078P0008
DOCUMENT ID.
3BHS799208 E01
MECHANICAL INSTALLATION
REV.
LANG.
PAGE
F
en
72/178