Ricoh M281 Series Service Manual page 336

Hide thumbs Also See for M281 Series:
Table of Contents

Advertisement

Electrical Components
[Reception Settings] -> [Reception File Settings] -> [Store].
[Specify User] in [User Tools] -> [Machine Features] -> [Facsimile Features] ->
[Reception Settings] -> [Stored Reception File User Setting].
[Notify Destination] in [User Tools] -> [Machine Features] -> [Facsimile Features] ->
[Reception Settings] -> [Folder Transfer Result Report].
Specified folder in [User Tools] -> [Machine Features] -> [Facsimile Features] ->
[Send Settings] -> [Backup File TX Setting].
[Receiver] in [User Tools] -> [Machine Features] -> [Facsimile Features] ->
[Reception Settings] -> [Reception File Settings] -> [Output Mode Switch Timer].
[Store: Notify Destination] in [User Tools] -> [Machine Features] -> [Facsimile
Features] -> [Reception Settings] -> [Output Mode Switch Timer].
All the destination information shown on the display.
In the fax settings, address book data is stored with entry IDs, which the system
internally assigns to each data. The entry IDs may be changed due to
re-assigning in backup/restore operations.
4. Make sure that there is no transmission standby file. If any standby file exists, ask the
customer to delete it or complete the transmission.
8.
Turn OFF the main power and unplug the power cord.
9.
Turn ON the main power again to discharge the residual charge.
10. Replace the NVRAM with a new one.
11. Turn ON the main power.
For SP 5300/5310, SC995 will be displayed after turning ON the main power.
For MP 501/601, SC995 might be internally issued after turning ON the main power.
After turning ON the main power, SC870 will occur and the address book data will be
cleared.
12. For MP 501/601, change the following SP settings for the operation panel after turning
ON the main power.
SP5-748-101: (OpePanel Setting: Op Type Action Setting): Change bit 0 from "0" to "1".
SP5-748-201: (OpePanel Setting: Cheetah Panel Connect Setting): Change the value
from "0" to "1".
13. For MP 501/601, change the Flair API SP values.
SP5-752-001 (Copy FlairAPIFunction Setting): Change bit 0 from "0" to "1".
SP1-041-001 (Scan:FlairAPI Setting) in Scanner SP: Change bit 0 from "0" to "1".
SP3-301-001 (FAX:FlairAPI Setting) in Fax SP: Change bit 0 from "0" to "1".
14. Turn OFF/ON the main power with the SD card where the NV-RAM data has been
uploaded in SD slot 2.
D255/D256/M281/M282
4-142
SM

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

D255 seriesD256M282M281-1D255-17

Table of Contents