6.2 SERVICE CALL 101-195
6.2.1 SC100 (ENGINE: SCANNING) (MP 501/601 ONLY)
SC No.
Type
SC101-01
D
SM
Error Name/Error Condition/Major Cause/Solution
Lamp Error (Scanning)
The white level peak did not reach the prescribed threshold
when the white guide plate was scanned.
Error detection timing;
During a scan from the exposure glass:
When the scanning of white guide plate is completed. (when
the SHGH is negated)
During a scan from ARDF:
During the shading operation.
When the scanning of white guide plate is completed. (when
the SHGH is negated)
Condensation in scanner unit
Connector disconnected
Scanner Carriage defective
BiCU defective
Harness defective
White Guide Plate dirty or defective
IOB defective
6-5
Service Call 101-195
D255/D256/M281/M282