Code
Meaning
The other terminal is not
0-15
capable of specific functions.
CFR or FTT not detected after
0-16
modem training in confidential
or transfer mode
Communication was
0-17
interrupted by pressing [Stop]
Facsimile data not received
0-20
within 6 s of retraining
SM
Suggested Cause/Action
The other party is unable to accepting the
following functions, or the other party's memory
is full.
Confidential RX
Transfer function
SEP/SUB/PWD/SID
Check the connection.
Replace the FCU.
Try adjusting the TX level and/or cable
equalizer settings.
The other machine may have
disconnected, or it may be defective. Try
sending to another machine.
If the RX signal level is too low, there may
be a line problem.
Reference:
See error code 0-08.
If [Stop] was not pressed and this error
keeps occurring, replace the operation
panel or the operation panel drive board.
Check the connection.
Replace the FCU.
Check for line problems.
Try calling another fax machine.
Try adjusting the reconstruction time for
the first line and/or RX cable equalizer
setting.
Reference:
Reconstruction time - G3 Switch 0A, Bit 6
RX cable equalizer - G3 Switch 07 (PSTN)
25