3. Connection

3.1. Connecting a Twisted Pair Port

● Connection Cable
Use a CAT5E or higher straight cable (twisted pair cable) with 8P8C RJ45 modular
plugs.
● Network Configuration
100 m or shorter
Figure 3-4 Connection configuration example
The length of the cable connecting this Switching Hub and a device must be 100 m
or shorter. When a terminal or a LAN device with auto negotiation function is con-
nected to a port, the port is automatically configured to the most appropriate per-
formance mode. When a terminal or a device without auto negotiation function is
connected to a port, this Switching Hub automatically determines and sets the
communication speed; however, the full-duplex/half-duplex configuration is set at
half-duplex because the full-duplex/half-duplex capability cannot be determined.
When connecting a terminal or a device without auto negotiation function, set the
connection mode of the port to Fixed. For detailed configuration procedure, refer
to Section 4.2.2 of Operation Manual for Menu Screens.
Note:
If connection mode is set to a fixed value, Auto-MDI/MDI-X function does not
work. Therefore, you need to use a cross cable for connections between
Switching Hub.