Connecting The Inlet; Connecting The Venting Pipe - Kessel Aqualift F Mono Instructions For Installation, Operation And Maintenance

Lifting station for wastewater with and without sewage, for free-standing set-up in frost-protected rooms
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 39
4.2.1

Connecting the inlet

The inlet can optionally be mounted to one of the pre-scored
areas (see 2.4.1). Make sure that:
The inlet is located above the level sensor for pump
switch-on. Otherwise backwater will occur in the inlet pipe.
Alternatively, the switching points must be adapted.
Do not position the inlet in the direct vicinity of the level sensor
since the function of the sensor could be impaired by soiling
and the wastewater inflow.
Use matching drill bit and all-round
seal.
4.2.2

Connecting the venting pipe

Connect the venting pipe to the venting connection <18>
(according to DIN EN 12056-4).
Connections and clamps should have sound-reducing
properties.