Appendix C: MIDI
13.4.27 Parameter change
When transmission is enabled by receiving a Request of Remote meter, the
specified meter information is transmitted every 50 msec for 10 seconds.
When you want to transmit meter information continuously, a Request
must be transmitted continuously within every 10 seconds.
Reception
This is echoed if [Parameter change ECHO] is ON.
Transmission
When transmission has been enabled by a Request, the parameter specified
by Address will be transmitted on the [Rx CH] channel at 50 msec intervals
for a duration of 10 seconds.
Transmission will be disabled if the power is turned off and on again, or if
the PORT setting is changed.
If [Parameter change ECHO] is ON, this message will be retransmitted
without change.
STATUS
11110000 F0
ID No.
01000011 43
SUB STATUS 0001nnnn 1n
GROUP ID
00111110 3E
MODEL ID
00000110 06
ADDRESS
00100001 21
0mmmmmmm mm
0mmmmmmm mm
0mmmmmmm mm
DATA
0ddddddd dd
0ddddddd dd
:
:
EOX
11110111 F7
13.4.28 Parameter request
Reception
If [Parameter change RX] is ON and the [Rx CH] matches the Device
Number included in the SUB STATUS, these messages are received. If [Pa-
rameter change ECHO] is ON, these messages are echoed.
When this is received, data of the specified address is transmitted on the
[Rx CH] at intervals of 50 msec as a rule, for a period of 10 seconds.
If Address UL= 0x7F is received, transmission of all meter data will be halt-
ed immediately. (disable)
Transmission
If [Parameter change ECHO] is ON, this message will be retransmitted
without change.
STATUS
11110000 F0
ID No.
01000011 43
SUB STATUS 0011nnnn 3n
GROUP ID
00111110 3E
MODEL ID
00000110 06
ADDRESS
00100001 21
0mmmmmmm mm
0mmmmmmm mm
mmmmmmm
mm
0ccccccc ch
0ccccccc cl
EOX
11110111 F7
13.4.29 Parameter change (Remote time counter)
When transmission is enabled by receiving a Request of Remote Time
Counter, the Time Counter data is transmitted every 50 msec for 10 sec-
onds. When you want to transmit Counter information continuously, a
Request must be transmitted within every 10 seconds.
Reception
This is echoed if [Parameter change ECHO] is ON.
Transmission
When transmission is enabled by receiving a Request, the Time Counter
information is transmitted on [RxCH] channel every 50 msec for 10 sec-
onds.
Transmission will be disabled if the power is turned off and on again, or if
the PORT setting is changed.
If [Parameter change ECHO] is ON, this message will be retransmitted
without change.
STATUS
11110000 F0
DM2000 Version 2—Owner's Manual
(Remote meter)
System exclusive message
Manufacture's ID number (YAMAHA)
n=0-15 (Device number=MIDI Channel)
MODEL ID (digital mixer)
DM2000
Remote meter
ADDRESS UL
ADDRESS LU
ADDRESS LL
data1 H
Data1 L
End of exclusive
(Remote meter)
System exclusive message
Manufacture's ID number (YAMAHA)
n=0-15 (Device number=MIDI Channel)
MODEL ID (digital mixer)
DM2000
Remote meter
ADDRESS UL
ADDRESS LU
ADDRESS LL
Count H
Count L
End of exclusive
System exclusive message
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS 0001nnnn 1n
MODEL ID (digital mixer)
GROUP ID
00111110 3E
DM2000
MODEL ID
00000110 06
Remote Time counter
ADDRESS
00100010 22
0:Time code, 1:Measure.Beat.Clock
0000tttt 0t
Hour / Measure H
0ddddddd dd
Minute / Measure L
0ddddddd dd
Second / Beat
DATA
0ddddddd dd
Frame / Clock
0ddddddd dd
End of exclusive
EOX
11110111 F7
13.4.30 Parameter request (Remote time counter)
Reception
If [Parameter change RX] is ON and the [Rx CH] matches the Device
Number included in the SUB STATUS, these messages are received. If [Pa-
rameter change ECHO] is ON, these messages are echoed.
When this is received, the Time Counter information is transmitted on the
[Rx CH] channel every 50 msec for 10 seconds.
When the second byte of Address is received on 0x7F, data transmission
will be halted immediately. (disable)
Transmission
If [Parameter change ECHO] is ON, this message will be retransmitted
without change.
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS 0011nnnn 3n
MODEL ID (digital mixer)
GROUP ID
00111110 3E
DM2000
MODEL ID
00000110 06
Remote Time counter
ADDRESS
00100010 22
0:Transmission request,
0ddddddd dd
0x7F:Transmission stop request
End of exclusive
EOX
11110111 F7
13.4.31 Parameter change
When transmission is enabled by receiving a Request of Automix status,
the Automix Status data is transmitted every second for 10 seconds. When
you want to transmit the Automix Status information continuously, the
Request must be transmitted continuously minimum within 10 seconds
interval. The data is transmitted continuously while the transmission is en-
abled, even when the Automix Status on the DM2000 has been changed.
Reception
This is echoed if [Parameter change ECHO] is ON.
Transmission
When the transmission is set to enable by receiving a Request. The Auto-
mix Status data is transmitted on the [Rx CH] channel every second for 10
seconds. The data is transmitted continuously while the transmission is
enabled, even when the Automix Status on the DM2000 has been changed.
Transmission will be disabled if the power is turned off and on again, or if
the PORT setting is changed.
If [Parameter change ECHO] is ON, this message will be retransmitted
without change.
System exclusive message
STATUS
11110000 F0
Manufacture's ID number (YAMAHA)
ID No.
01000011 43
n=0-15 (Device number=MIDI Channel)
SUB STATUS 0001nnnn 1n
MODEL ID (digital mixer)
GROUP ID
00111110 3E
DM2000
MODEL ID
00000110 06
Automix status
ADDRESS
00100011 23
00000000 00
Automix status H
0000dddd 0d
Automix status L
0000dddd 0d
End of exclusive
EOX
11110111 F7
(Automix status)

Advertisement