6
6-7 Understanding calibration
6. Configure the densitometer to factory defaults and save the settings. (See the
7. Turn on the PowerBook.
8. In the PowerBook Setup Control Panel, select Normal for Modem Controls.
9. Calibrate the densitometer, as described below.
T
O CALIBRATE THE
1. On the X-Rite DTP32, simultaneously press the two buttons marked MENU.
2. Press the p1 key until p2 appears.
3. Press the cal key.
4. Press the den key.
5. Position the strip guide at 5.
Strip guide
6. Insert the arrow end of the Auto-Cal strip into the entrance of the X-Rite DTP32 until
densitometer manual for details.)
Factory default settings for the X-Rite DTP32 are:
Page 1
LANG (ENG)
Page 2
BAUD (9600)
Page 3
DPT (on)
Page 4
DEF (off )
Page 5
M/M (max)
X-R
DTP32:
ITE
The words
MAIN MENU
appear in the display.
appears in the display.
CALIBRATION
CALIBRATING TRANSMISSION
the roller starts pulling the strip.
TONE (loud)
TYPE (ser)
HAND (xon)
AXMT (on)
SEP (spc)
DLIM (crlf )
X10 (off )
DAP (off )
LOCK (off )
is displayed, followed by the words
.
INSERT CAL STRIP