Dedicated Motor Outline Dimension Drawings - Mitsubishi Electric FR-A720-0.4K Instruction Manual

Fr-a700 series
Hide thumbs Also See for FR-A720-0.4K:
Table of Contents

Advertisement

6.4.2

Dedicated motor outline dimension drawings

Dedicated motor (SF-V5RU(H)) outline dimension drawings (standard horizontal type)
Frame Number 90L
SF-V5RU(H)
1K
Connector (for encoder)
MS3102A20-29P
L
R
50
B
A
KA
40
Exhaust
Suction
A
A
Direction of
XB
cooling fan wind
F
F
Mark for earthing
N
(grounding)
Earth (ground) terminal (M5)
W
Sliding distance
15
S
Frame leg viewed from above
Section AA
Frame Number 160M, 160L, 180M, 180L
SF-V5RU(H)
11K
,
15K
,
18K
Connector (for encoder)
MS3102A20-29P
L
A
B
KA
Exhaust
Suction
With guard
wires
Direction of
cooling fan wind
Mark for earthing
F
F
(grounding)
N
Earth (ground)
terminal (M8)
Sliding distance
W
4
S
Frame leg viewed
from above
Section AA
Dimensions table
SF-V5RU
SF-V5RU
SF-V5RU
SF-V5RU
Frame
Mass
K
K1
K3
K4
No.
(kg)
1
90L
24
2
1
100L
33
3
2
1
112M
41
5
3
2
132S
52
7
5
3
1
132M
62
11
7
5
2
160M
99
15
11
7
3
160L
113
18
138
180M
22
15
11
160
18
15
5
180L
200
30
7
238
200L
37, 45
22, 30
18, 22
255
55
37
30
11, 15
225S
320
Note) 1. Install the motor on the floor and use it with the shaft horizontal.
2. Leave an enough clearance between the fan suction port and wall to ensure adequate cooling.
Also, check that the ventilation direction of a fan is from the opposite load side to the load side.
3 The size difference of top and bottom of the shaft center height is
4 The 400V class motor has -H at the end of its type name.
KL
D
E
E
M
For cooling fan (A, B)
For motor (U, V, W)
Thermal protector (G1, G2)
A
B
U
V
W
G1
G2
,
22K
R
KL
110
D
90
A
A
50
XB
E
E
M
For motor (U, V, W)
For cooling fan (A, B, C)
For thermal protector (G1, G2)
A
B
C
D
E
F
H
256.5
114
90
183.6
70
62.5
198
284
128
100
207
80
70
203.5
230
278
135
112
228
95
70
226
253
303
152
132
266
108
70
265
288
322
171
132
266
108
89
265
288
412
198
160
318
127
105
316
367
434
220
160
318
127
127
316
367
438.5 225.5
180
363
139.5 120.5
359
410
457.5 242.5
180
363
139.5 139.5
359
410
483.5 267.5
200
406
159
152.5
401
500
277
225
446
178
143
446
0
-0.5
Frame Number 100L, 112M, 132S, 132M
SF-V5RU(H)
2K
,
3K
Connector (for encoder)
MS3102A20-29P
L
A
B
KA
Exhaust
Suction
Direction of
cooling fan wind
F
F
Mark for earthing
N
(grounding)
Earth (ground) terminal (M5)
Earthing (grounding) terminal (M4)
Frame Number 200L, 225S
SF-V5RU(H)
30K 37K
,
Connector (for encoder)
MS3102A20-29P
L
A
KA
Suction
With guard
wires
Direction of
Mark for earthing
cooling fan wind
F
(grounding)
Earth (ground)
terminal (M12)
Earthing (grounding)
terminal (M8)
Make sure to earth the earth terminal of the frame installation foot
as well as the earth terminal in the terminal box.
Motor
I
KA
KG KL(KP)
L
M
ML
N
53
65
220(210)
425
175
150
65
78
231
477
200
212
180
69
93
242
478
230
242
180
75
117
256
542
256
268
180
94
117
256
580
256
268
218
105
115
330
735
310
254
127
115
330
779
310
298
127
139
352
790
335
285
146
139
352
828
335
323
145
487
(546)
909
390
361
145
533
(592)
932
428
342
Outline dimension drawings
,
5K
,
7K
R
Q
KL
QK
D
A
A
40
XB
E
E
M
Sliding distance
W
ML
S
Frame leg viewed
Section AA
from above
,
45K
,
55K
R
B
140
D
110
Exhaust
A
A
70
XB
F
E
E
N
M
Sliding distance
W
S
Frame leg viewed
Section AA
from above
XB
Q
QK
R
S
T
U
W
56
168.5 24j6
7
4
8
63
60
45
193
28j6
7
4
8
70
60
45
200
28j6
7
4
8
89
80
63
239
38k6
8
5
10
89
80
63
258
38k6
8
5
10
108
323
42k6
8
5
12
108
345
42k6
8
5
12
121
351.5 48k6
9
5.5
14
121
370.5 55m6
10
6
16
133
425.5 60m6
11
7
18
149
432
65m6
11
7
18
4
4
(Unit: mm)
Terminal Screw
Size
U,V,W A,B,(C) G1,G2
M6
M4
M4
M6
M4
M4
M6
M4
M4
M6
M4
M4
M6
M4
M4
M8
M4
M4
M8
M4
M4
M8
M4
M4
M8
M4
M4
M10
M4
M4
M10
M4
M4