Leds - YASKAWA VIPA IM 053IP Manual

For vipa system slio
Hide thumbs Also See for VIPA IM 053IP:
Table of Contents

Advertisement

VIPA System SLIO

3.2.3 LEDs

Bus-Interface
HB300 | IM | 053-1IP00 | GB | 13-50
Changes of the IP address only take effect on PowerON or
an automatic reset. Changes during operation are not rec-
ognized!
LED
Description
·
PWR
green
·
SF
red
BB
·
MS
(module
BB
state)
green/
·
red
BB
BB
BB
·
NS (net-
work state)
BB
green/
BB
red
BB
BB
LNK1
BB
green
on: ● | off: ○ | blinking (2Hz): BB | not relevant: X
1) Please contact VIPA.
Hardware description
Bus interface is power supplied
Error at Ethernet or at the System SLIO
bus. Please perform a power cycle.
Unrecoverable error - Please contact the
VIPA hotline
Module state: Operational
Module state: Standby (Idle) - BASP acti-
vated
1
Unrecoverable error
. Please perform a
power cycle.
Recoverable error (e.g. error in configura-
tion)
Module state: Selftest
EtherNet/IP communication: RUN
There is no connection to a Scanner
Recoverable Ethernet/IP error
Module state: Selftest
Network activity
No network activity
Structure > LEDs
35

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vipa 053-1ip00

Table of Contents