VIPA System SLIO
Transitions

4.5 Web server

Access via IP address
Structure of the web
page
HB300 | IM | 053-1IP00 | GB | 13-50
1 Transition from Idle to Operational: As soon as a communication
connection to at least one scanner exists respectively at least one
scanner is in "Run mode".
2 Transition Operational to Idle: As soon there is no communication
connection to a scanner respectively every scanner is in "Idle
mode". With the release of the last communication connection by
the scanner, the EtherNet/IP coupler automatically switches to
Idle mode.
3 With a configuration error e.g. in the FORDWARD_OPEN Config
Assembly, the EtherNet/IP coupler switches directly from Idle
mode to Error mode and shows this by the blinking red MS LED.
4 If e.g. the Ethernet cable is removed during operation the
EtherNet/IP coupler switches directly from Operational mode to
Error mode. BASP is activated. By plugging the Ethernet cable the
EtherNet/IP coupler automatically return to Operational mode, if
an communication connection to a scanner still exists. Otherwise
it switches to Idle mode.
The integrated web server can be accessed by means of this IP
address data and these may be changed there. On delivery the
EtherNet/IP coupler has the following IP address data:
Subnet mask:
IP address:
Please consider the System SLIO power and clamp mod-
ules do not have any module ID. These may not be recog-
nized by the EtherNet/IP coupler and so are not listed and
considered during slot allocation.
Further within EtherNet/IP the slots are designated a
'EtherNet/IP-Slot' .
The counting always begins with 0.
The web page is built dynamically and depends on the number of
modules, which are connected to the EtherNet/IP coupler.
Deployment
255.255.255.0
192.168.1.1
Web server
43