Safety Advice (Precautions) - WAGO 750-461 Series Manual

2ai pt100/rtd, 2-channel analog input for resistance sensors for wago-i/o-system 750
Hide thumbs Also See for 750-461 Series:
Table of Contents

Advertisement

WAGO-I/O-SYSTEM 750
750-461 2AI Pt100/RTD
Pos: 18.12 /Alle Serien (Allgemeine Module)/Überschriften/Ebene 2/Sicherheitshinweise - Überschrift 2 @ 6\mod_1260180299987_21.docx @ 46724 @ 2 @ 1
2.2

Safety Advice (Precautions)

Pos: 18.13 /Alle Serien (Allgemeine Module)/Sicherheits- und sonstige Hinweise/Einleitung Sicherheitshinweise Hardware @ 6\mod_1260180170493_21.docx @ 46720 @ @ 1
For installing and operating purposes of the relevant device to your system the
following safety precautions shall be observed:
Pos: 18.14.1 /Alle Serien (Allgemeine Module)/Sicherheits- und sonstige Hinweise/Gefahr/Gefahr: Nicht an Geräten unter Spannung arbeiten! @ 6\mod_1260180365327_21.docx @ 46727 @ @ 1
Do not work on devices while energized!
All power sources to the device shall be switched off prior to performing any
installation, repair or maintenance work.
Pos: 18.14.2 /Serie 750 (WAGO-I/O-SYSTEM)/Wichtige Erläuterungen (alte Struktur)/Sicherheits- und sonstige Hinweise/Gefahr/Gefahr: Einbau 0750-xxxx nur in Gehäusen, Schränken oder elektrischen Betriebsräumen! @ 6\mod_1260180556692_21.docx @ 46731 @ @ 1
Install the device only in appropriate housings, cabinets or in electrical
operation rooms!
The WAGO-I/O-SYSTEM 750 and its components are an open system. As such,
install the system and its components exclusively in appropriate housings,
cabinets or in electrical operation rooms. Allow access to such equipment and
fixtures to authorized, qualified staff only by means of specific keys or tools.
Pos: null /Alle Serien (Allgemeine Module)/Sicherheits- und sonstige Hinweise/Gefahr/Gefahr: Trennvorrichtung und Überstromschutz @ 33\mod_1543915978439_21.docx @ 512267 @ @ 1
Ensure disconnect and overcurrent protection!
The device is intended for installation in automation technology systems.
Disconnect protection is not integrated. Connected systems must be protected by
a fuse.
Provide suitable disconnect and overcurrent protection on the system side!
Pos: 18.14.4 /Alle Serien (Allgemeine Module)/Sicherheits- und sonstige Hinweise/Gefahr/Gefahr: Unfallverhütungsvorschriften beachten! @ 6\mod_1260180657000_21.docx @ 46735 @ @ 1
Pos: 18.14.5 /Alle Serien (Allgemeine Module)/Sicherheits- und sonstige Hinweise/Gefahr/Gefahr: Auf normgerechten Anschluss achten! @ 6\mod_1260180753479_21.docx @ 46739 @ @ 1
Ensure a standard connection!
To minimize any hazardous situations resulting in personal injury or to avoid
failures in your system, the data and power supply lines shall be installed
according to standards, with careful attention given to ensuring the correct
terminal assignment. Always adhere to the EMC directives applicable to your
application.
Pos: null /Alle Serien (Allgemeine Module)/Sicherheits- und sonstige Hinweise/Achtung/Achtung: Einwandfreie Kontaktierung zur Tragschiene gewährleisten! @ 34\mod_1550481407638_21.docx @ 530599 @ @ 1
Ensure proper contact with the DIN-rail!
Proper electrical contact between the DIN-rail and device is necessary to
maintain the EMC characteristics and function of the device.
Pos: 18.15.2 /Alle Serien (Allgemeine Module)/Sicherheits- und sonstige Hinweise/Achtung/Achtung: Defekte oder beschädigte Geräte austauschen! @ 6\mod_1260180857358_21.docx @ 46743 @ @ 1
Important Notes
13
Manual
Version 1.4.1

Advertisement

Chapters

Table of Contents
loading