Conversion From One Type Of Gas To Another - Riello ALU PRO power Series Instructions For The Installer And The Technical Assistance Centre

Aluminium condensing boilers
Table of Contents

Advertisement

b
THIS CHAPTER IS NOT VALID FOR COUNTRIES WHERE IT IS NOT POSSIBLE TO CARRY OUT THIS TYPE OF
CONVERSION.
The ALU PRO power boilers are supplied to operate
with G20 (methane gas). They can, however, be con-
verted to operate with G25 or G31 using the relative Kit
supplied.
b
r
Contact the
Technical Assistance Centre.
Before carrying out the conversion:
- Switch off the electricity supply setting the system's
main switch and that of the control panel to "off"
- Close the gas shut-off tap
- Remove the top panel
- Disconnect the line gas valve
- With a TORX wrench unscrew the screws (3) and free
the gas valve (1) from the venturi pipe unit (2)
- Replace the diaphragm (4), fitted on the gas valve, with
the one supplied with the kit, whose diameter is shown
in the table below.
DIAPHRAGM diameter (Ø)
G20
G25
G31
- Put back the gas valve and carry out all the calibration
operations described in the section "Setting the com-
bustion parameters" on page 51.
b
After installing the kit, check the seals on all connec-
tions made.
b
The pressures to have on the gas network are
shown in the table below.
NOMINAL gas feeding pressures
G20
G25
G31

CONVERSION FROM ONE TYPE OF GAS TO ANOTHER

7.7
NO (not present)
5.8
20 mbar
25 mbar
37 mbar
b
Conversions should only be carried out by the
r
Technical Assistance Centre or by authorised
personnel, even when the boiler has already been
installed.
b
On completion of the conversion, adjust the boil-
er again following the instructions given in the
"Calibrating combustion parameters" section".
1
MINIMUM gas feeding pressure
G20
TECHNICAL ASSISTANCE CENTRE
2
3
4
13 mbar
55