Regular maintenance is mandatory according to Pres.
Decree 26 August 1993 no. 412, and it is essential for
the safety, the efficiency and long life of the boiler. Proper
maintenance keeps consumption and emissions down,
and ensures that the boiler continues to operate reliably
over time.
Before starting maintenance operations:
- Switch the electricity supply "off" using the system's
main switch and the one on the main control panel
- Close the fuel shut-off taps.
- Remove the split pin (1), detach the corrugated con-
densate drain hose, and remove the siphon unscrew-
ing the two screw caps (2).
- Remove the float (3) and clean all the components.
Once the cleaning operations are finished, reassemble
all the components, following the above instructions in
the reverse order.
0 = domestic hot water pump upstream
1 = domestic hot water pump downstream
b
On completion of maintenance operations, the origi-
nal settings must be restored and combustion fumes
analysed to verify everything is working correctly.

CLEANING THE CONDENSATE DRAIN AND SIPHON

Minimum
Maximum
of the water equalisation device
of the water equalisation device
2 = zone pump downstream
of the water equalisation device
0 = function disabled
1 = function enabled
0 = function disabled
1 = function enabled

MAINTENANCE