7000 ACI PLUS
EN INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the 7000 ACI PLUS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Riello 7000 ACI PLUS

  • Page 1 7000 ACI PLUS EN INSTALLATION, OPERATION AND MAINTENANCE MANUAL...
  • Page 2 RIELLO 7000 ACI 2000 PLUS 20137624 Thank you again, and keep up the good work, MODEL (Cold version) CODE Riello S.p.A. RIELLO 7000 ACI 800 PLUS C 20136268 RIELLO 7000 ACI 1000 PLUS C 20136269 CONFORMITY RIELLO 7000 ACI 1500 PLUS C...
  • Page 3: Table Of Contents

    CONTENTS GENERAL General Safety Information ..... . 4 Precautions........4 Description of the appliance .
  • Page 4: General

    GENERAL GENERAL GENERAL SAFETY INFORMATION 2 PRECAUTIONS The operation of any appliance that uses electrical power de- mands that a number of fundamental safety precautions be re- Check that the product is complete, undamaged and as or- spected. In particular: dered as soon as you receive it.
  • Page 5: Description Of The Appliance

    − CFC and HCFC free PEXL + Soft polyurethane insulation and an elegant external casing to reduce heat loss and im- prove efficiency 7000 ACI PLUS buffer tanks are easy to integrate in systems in which boilers or other products act as auxiliary heat sources.
  • Page 6: Technical Specifications

    (*) In accordance with DIN 4708 with a T of 20°C (80°/60°C) at the coil. 7 LOCATION OF SENSORS 7000 ACI PLUS buffer tanks incorporate sockets for temperature control sensors. The actual positioning of sensors depends on what components, water connections and control device are installed.
  • Page 7: Overall Dimensions And Water Fittings

    GENERAL GENERAL 8 OVERALL DIMENSIONS AND WATER FITTINGS 7000 ACI PLUS - PLUS C DESCRIPTION 1000 1500 2000 Temperature gauge socket 1/2" F Ø Vent valve fitting 1"1/4 F Ø Sensor sockets 1/2" F Ø Fitting for electrical heating element (not supplied) 1 1/2”...
  • Page 8: Installer

    INSTALLER 9 UNPACKING THE PRODUCT 10 HANDLING 7000 ACI PLUS buffer tanks are delivered in a single pack- Once you have removed the outer packaging, proceed as follows age, protected by a plastic bag and secured to a wooden pallet.
  • Page 9: Place Of Installation

    11 PLACE OF INSTALLATION 12 INSTALLATION IN OLDER SYSTEMS AND SYSTEMS REQUIRING MODERNISATION 7000 ACI PLUS buffer tanks can be installed in any room where there is no specific requirement for an electrical protec- When installing 7000 ACI PLUS buffer tanks in old systems or tion rating higher than IP X0D.
  • Page 10: End User

    END USER END USER END USER INSTRUCTIONS Refer to the GENERAL SAFETY INFORMATION and PRECAUTIONS section for safety-related information. 13 START-UP 14 TEMPORARY SHUTDOWN The buffer tank must be put into service for the first time by To reduce impact on the environment and save energy, before personnel from the manufacturer’s Technical Assistance Service.
  • Page 11: Technical Assistance Service

    TECHNICAL ASSISTANCE SERVICE TECHNICAL ASSISTANCE SERVICE 17 RECYCLING AND DISPOSAL At the end of its useful working life, do not abandon the buffer tank in the environment, but dispose of it through the proper chan- nels in accordance with applicable legislation. 18 TROUBLESHOOTING FAULT CAUSE...
  • Page 12 The manufacturer strives to continuously improve all products. Appearance, dimensions, technical specifications, standard equipment and accessories are therefore liable to modification without notice.