FAMILY CX

For fault E041

If the pressure drops below the safety threshold of 0.3 bar the boiler displays
the fault code "E041 - WATER TRANSDUCER PRESS OK TO FILL THE
SYSTEM" for a transitional time of 10 min during which it is possible to start
the semi-automatic loading procedure, pressing the "ENTER" key to fi ll the
system (the procedure can only be started in SUMMER or WINTER).
WATER TRANSDUCER
PRESS OK FOR AUTO FILL
During the loading phase the scrolling message "SEMI-AUTOMATIC
FILLING IN PROGRESS" is displayed at the foot of the screen, while the
pressure highlighted on the display should start to rise.
When the loading is fi nished the scrolling message "SEMI-AUTOMATIC
FILLING FINISHED" is displayed at the foot of the page.
When the transitional time has fi nished, if the fault persists the fault code
E040 is displayed.
When the boiler has fault E040 manual loading should be carried out using
the fi ller tap (A) until the pressure is between 1 and 1.5 bar.
Then close the fi lling tap, making sure to hear the mechanical snap.
At the end of the procedure, proceed with the automatic vent cycle as
described in "Filling the heating system and eliminating air"
A
b
If the drop in pressure is very frequent, contact the Technical
Assistance Centre.

For fault E060

The boiler is working normally, but does not provide any stability of the
domestic hot water temperature that, in any event, is supplied at a
temperature of around 50°C. The intervention of the Technical Assistance
Service is required.

For fault E091

The boiler has an auto-diagnostic system which, based on the total number
of hours in certain operating conditions, can signal the need to clean the
primary exchanger (alarm code E091).
Once the cleaning operation has been completed, reset to zero the total
hour meter with special kit supplied as an accessory following procedure
indicated below:
- access the technical parameters as explained in the section" Accessing
the technical parameters".
- select RESET FLUE GAS PROBE with the "UP" and "DOWN" keys ,
confirming the selection
26
E041
WEATHER COMPENSATION
COMBUSTION ANALYSIS
EXHAUST PROBE RESET
INSTALLER
- select CONFIRM to confirm the reset of the flue gas probe meter or else
"BACK" to cancel the operation
THE PARAMETER WILL
CONFIRM
CONFIRM OR DELETE SELECTION
Note: The meter resetting procedure should be carried out after each
in-depth cleaning of the primary exchanger or if this latter is replaced.
The total hours can be verified in the following way:
- select INFO on the initial screen of the REC10 and press "ENTER"
FRI
18/05/2013
MENU
INFO
HOT WATER TEMPERATURE
- using the "UP" and "DOWN" keys select FLUE GAS PROBE and press
"ENTER" to display the value of the flue gas probe meter.
TECHNICAL
RANGE RATED
CALIBRATION
BE CHANGED
CANCEL
PLANT
12:17
bar
1.3
STATE
°C
30
.3
SET